Laserfiche WebLink
Onsite Permit 555-20-009261-PRMT Page 2 of 3 <br /> Schedule or track inspections at www.buildingpermits.oregon.gov <br /> Call or text the word "schedule"to 1-888-299-2821 use IVR Number:555074998065 <br /> Schedule using the Oregon ePermitting Inspection App, search"epermitting"in the app store <br /> Date issued 12/30/20 Expiration date 12130/21" <br /> Work dl scription NEW INSTALL 3 BORM SFD <br /> 9 3'5 <br /> Special Requirements <br /> Stake out required: No <br /> Groundwater type: Temporary Groundwater depth: N/A <br /> Other special rqmt: DRY WEATHER INSTALLATION ONLY MAY THROUGH SEPTEMBER OR WITH INSPECTOR <br /> APPROVAL <br /> Conditions of approval <br /> •Dry soil installation only(June 1 —October 1 unless otherwise authorized by the agent). <br /> •The system must be installed by the property owner or a licensed sewage disposal business <br /> (installer). <br /> •Vehicular traffic and livestock must be restricted from the system area. <br /> •AII roof drains must be directed away from the system <br /> •All tanks must be tested for watertightness and have a water-tight riser to the ground surface. <br /> Twenty-inch minimum diameter if less than 36-in deep. Thirty-inch minimum diameter if greater <br /> than 36-in deep. Maintain access to septic tank for pumping and service. <br /> •Meet all required setbacks <br /> •The system must be installed in the area approved during the site evaluation and in accordance <br /> with the construction plan approved by the agent, including any changes made by the agent. <br /> •AII work is to conform to OAR 340, Division 71 and 73. Make no changes in system location or <br /> specifications without approval by the agent. <br /> •For product approval information and manufacturer installation requirements see DEQ website <br /> at: http://www.oregon.gov/deq/Residential/Pages/Onsite.aspx <br /> •Efuent sewer. The effluent sewer must extend at least 5 feet beyond the septic tank before <br /> connecting to the distribution unit. It must be installed with a minimum fall of 4 inches per 100 feet <br /> and at least 2 inches of fall from one end of the pipe to the other. In addition, there must be a <br /> minimum difference of 8 inches between the invert of the septic tank outlet and either the invert of <br /> the header to the distribution pipe of the highest lateral in a serial distribution field or the invert of <br /> the header pipe to the distribution pipes of an equal distribution absorption field. <br /> •Header pipe from Distribution or Drop Box must be minimum 4-ft length, level, and bedded. <br /> •Each drainfield trench must be level within a tolerance of plus or minus 1-inch. <br /> -Serial distribution, each trench bottom to be level and on contour. Use Drop box(es). <br /> 12/30/20:12:57:58PM Page 2 of 3 ONS_OnsitePermit_pr <br />