Laserfiche WebLink
!l ! <br /> Orenco <br /> S Y S T E M S <br /> (f1 lIl <br /> ane a <br /> 808 —1 ®© <br /> �0CIO <br /> �00 0I0 <br /> I,_=e� •Zr� TT'pp <br /> I <br /> © O <br /> f0000000000 <br /> • <br /> © O o8 <br /> / ° _© <br /> 111 I IIIA <br /> Orenco S-Series Simplex Control Panel(S1E(MCT shown) <br /> Standard Features <br /> Feature Specifications* <br /> 1.Motor-start contactor 120 VAC:17 FLA,1 hp(0.75 kW),2.5 million cycles at FLA <br /> 240 VAC:17 FLA,3 hp(2.24 kW),2.5 million cycles at FLA <br /> 2.Auto/Off/Man toggle switch Single-pole,double-throw HOA switch <br /> 3.Controls circuit breaker '10 A,OFF/ON switch,single pole,DIN rail mounting with thermal magnetic tripping characteristics <br /> 4.Pump circuit breaker 20A,OFF/ON switch,single pole(120 VAC)or double pole(240 VAC),DIN rail mounting with thermal magnetic <br /> tripping characteristics <br /> 5.Audible alarm 95 dB at 24 in.(610 mm),warble-tone sound;gasketed,UL Type 4X(IP66) <br /> 6.Audible alarm silence relay Automatic reset,DIN rail mount <br /> 7.Visible alarm 7,8-In.(22-mm)diameter red lens,"Push-to-silence,"UL Type 4X(IP66),1 W LED light <br /> 8.Enclosure UV-resistant fiberglass and stainless steel,UL Type 4X(IP66) <br /> Optional Features • <br /> Feature Specifications* Product code adder <br /> Intrinsically safe Listed per UL 698A,for Class 1 Div.1,groups A,B,C,D hazardous locations IR <br /> control relays (Requires larger enclosure) <br /> Programmable timer Repeat cycle from 0.05 seconds to 30 hours;separate variable controls for OFF&ON time periods PT <br /> Redundant off relay DIN rail mount;provides a secondary off;sounds alarm upon low level condition RO <br /> Elapsed time meter 7-digit,non-resettable;limit of 99,999 hours;accurate to 0.01 hours ETM <br /> Event counter 6-digit,non-resettable CT <br /> Heater anti-condensation heater;self-adjusting:radiates additional wattage as temperature drops HT <br /> Pump run light 7,8-in.(22-mm)diameter green lens;UL Type 4X(IP66),1 W LED light PRL <br /> Power light 7,8-in.(22-mm)diameter green lens;UL Type 4X(IP66),1 W LED light PL <br /> Surge arrestor Status light on unit;protects incoming power supply from electrical surges SA <br /> Test Switch Momentary switch for alarm testing TS <br /> 'All voltages are 120 VAC unless otherwise noted. <br /> NTD-CP-S-1 Orenco Systems°Inc.,814 Airway Ave.,Sutherlin,OR 97479 USA•800-348-9843•541-459-4449•www.orenco.com <br /> Rev.2.1,©04/18 <br /> Page 2 of 2 <br /> I'- <br />