Approved EZflow Products <br /> As required by DEQ or local unit of government with D. EZflow 1201 P will be sized at the same required linear foot <br /> jurisdiction, sod or seed the drainfield area to control sizing for standard 2-foot wide gravel trench. For example, if <br /> erosion, as may be required by permit or local policy. the sizing for a 2-foot gravel trench requires 100-linear feet <br /> of trench,the 1201 P system will be sized at 100-linear feet. <br /> EZflow is approved in Oregon by the DEQ and the Uniform <br /> Building Code Division. The 1202H/1202H-GEO <br /> The 1202H drainfield system (two, 12-inch diameter <br /> DEQ approvals include: bundles) may be used in a horizontal configuration within <br /> •Standard disposal trenches a 24-inch wide disposal trench.The bundles shall be <br /> • Capping fill systems placed side-by-side and in contact with each other. Serial <br /> •Sandfilter gravel-less absorption trenches distribution methods limit the maximum effluent depth to <br /> •Seepage trenches no more than 6-inches higher than the invert level of the <br /> •Steep slope systems perforated piping within the higher trenches.The minimum <br /> •Curtain drains backfill depth is 6-inches when equal distribution methods <br /> •Tile dewatering systems are used, and 12-inches with serial distribution methods. <br /> • Pressure distribution systems The brand 1202H will be sized at the same required linear <br /> foot sizing for standard 2-foot wide gravel trench. For <br /> Building Code approvals include: example, if the sizing for a 2-foot gravel trench requires <br /> • Foundation drains 100-linear feet of trench,the 1202H system will be sized at <br /> • Roof drain systems 100-linear feet.The bundle with pipe may be installed on <br /> either side within the trench. <br /> Standard Disposal Trenches <br /> The 1201P/1201P-GEO 1202H-GEO <br /> A. The 1201P drainfield system consists of one, 12-inch di- <br /> ameter bundle across the bottom of a trench 12-to-24 inches ESTABLISH <br /> 6"MIN.COVER <br /> VEGETATIVE COVER <br /> wide.The 1201 P bundle contains aggregate and a four-inch <br /> OR PER CODE <br /> diameterperforated flexibleplastic pipe as is typically used in 1 �-'"`i ' ''�' ''�,1•oi1 <br /> P p Yp Y --;,-, - . <br /> septic system drainlines.The pipe shall be certified as com- <br /> plying <br /> with ASTM F-667.The netting for the central bundle is <br /> tied off at both ends of the pipe.The pipe may be connected {r <br /> by an internal coupling device to allow continuous flow from 12" 1 ; » ' _ • 4"PERFORATED PIPE <br /> one section to the next. <br /> lI• C. <br /> 12"EZflow <br /> B. The difference between 1201P and 1201P-GEO is the I 24"MIN. BUNDLE(TYP.) <br /> TRENCH <br /> GEO filter fabric.The top of the bundle contains a filter fabric WIDTH <br /> pre-manufactured in between the netting and aggreate. The Figure 2 <br /> fabric is inserted to prevent soil instrusion.The installer shall <br /> make sure the fabric is on top before final backfilling. The 1003T <br /> The 1003T product(three, 10-inch diameter bundles) may be <br /> C. Site, soil and design requirements of the 1201 P system used in either a triangular or horizontal configuration at all lo- <br /> shall be the same as required for the standard stone filled cations where a gravity-fed disposal trench (containing drain <br /> disposal system (containing drain media 12-inches deep) as media 12-inches deep) would otherwise be allowed. The <br /> described in OAR Chapter 340, Divisions 71 &73. bundles shall be placed in a triangular configuration when in- <br /> stalled within a 24-inch wide trench.One bundle shall contain <br /> 1201P-GEO pipeing and be centered and in contact with the other two <br /> NATIVE BACKFILL bundles. When used in a horizontal configuration, the bun- <br /> 6"MIN.COVER ESTABLISH <br /> OR PER COD VEGETATIVE COVER dles must be placed side-by-side and in contact with each <br /> other, within a trench at.least 30-inches wide. The center <br /> `. ; : FILTER FABRIC bundle shall contain piping. Serial distribution methods limit <br /> the maximum effluent depth to no more than 6-inches higher <br /> •= than the invert level of the perforated piping within the higher <br /> 's�:- S7 PERFORATED PIPE trenches.The minimum backfill depth is 6-inches when equal <br /> 12^EZflow distribution methods are used, and 12-inches with serial dis- <br /> 12"-24" <br /> (TYP.)BUNDLE( ) tribution methods. EZflow 1003T will be sized e at the same <br /> WIDTH <br /> required linear foot sizing for standard 2-foot wide gravel <br /> Figure 1 q <br /> Contact Infiltrator Water Technologies'Technical Services Department for assistance at 1-800-221-4436 <br />