Laserfiche WebLink
statements on the application. <br /> (e) No person shall violate any provision of the Building Code. <br /> (f)No person shall disobey any lawful notice or order of the Building <br /> Official. <br /> (g) A violation of this section is subject to a civil penalty. <br /> 56.215 "DANGEROUS As used in SRC 56.200 to 56.390, any building or structure which has <br /> BUILDING" DE- any or all of the conditions or defects hereinafter described shall be <br /> FINED. deemed to be a dangerous building,provided that such conditions or <br /> defects exist to the extent that the life, health, property, or safety of the <br /> public or its occupants are endangered: <br /> (a) Whenever any door, aisle, passageway, stairway, or other means of <br /> exit is not of sufficient width or size, or is not so arranged as to provide <br /> safe and adequate means of exit in <br /> case of fire or panic. <br /> (b) Whenever the stress in any materials, member or portion thereof, due <br /> to all dead and live loads, is more than one and one-half times the <br /> working stress or stresses allowed in the UBC for new buildings of <br /> similar structure, purpose, or location. <br /> (c) Whenever any portion thereof has been damaged by fire, earthquake, <br /> wind, flood, or by any other cause, to such an extent that the structural <br /> strength or stability thereof is materially less than it was before such <br /> catastrophe and is less than the minimum requirements of the UBC for <br /> new buildings of similar structure, purpose, or location. <br /> (d) Whenever any portion or member or appurtenance thereof is likely to <br /> fail, or to become detached or dislodged, or to collapse and thereby injure <br /> persons or damage property. <br /> (e) Whenever any portion of a building, or any member, appurtenance or <br /> ornamentation on the exterior thereof is not of sufficient strength or <br /> stability, or is not anchored, attached, or fastened in place so as to be <br /> capable of resisting a wind pressure of one-half of that specified in the <br /> UBC for new buildings of similar structure, purpose, or location without <br /> exceeding the working stresses permitted in the UBC for such buildings. <br /> (f) Whenever any portion thereof has wracked, warped, buckled, or <br /> settled to such an extent that walls or other structural portions have <br /> materially less resistance to winds or earthquakes than is required in the <br /> case of similar new construction. <br /> (g)Whenever the building or structure, or any portion thereof, because of <br /> (i) <br /> dilapidation, deterioration, or decay; (ii)faulty construction; (iii)the <br /> removal, movement, or instability of any portion of the ground necessary <br /> for the purpose of supporting such building; <br /> (iv)the deterioration, decay, or inadequacy of its foundation; or (v) any <br /> other cause, is likely to partially or completely collapse. <br /> (h) Whenever, for any reason, the building or structure, or any portion <br /> thereof, is manifestly unsafe for the purpose for which it is being used. <br /> (i) Whenever the exterior walls or other vertical structural members list, <br /> Page 9 of 10: Enforcement Order to Abate <br />