My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
11853059
Images9
>
Public Works - Permits
>
Building
>
FOR PUBLIC VIEW ON INTERNET
>
COMPLETED FILES - INACTIVE
>
20-XXXXXX
>
11853059
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/29/2023 2:03:52 PM
Creation date
9/18/2023 12:13:06 PM
Metadata
Fields
Template:
Permits
Permit Address
9565 ELKHORN WOODS CIR SE
Permit City
Lyons
Permit Number
555-20-004636-PRMT
Parcel Number
093E02DD00500
Permit Type
Septic
Permit Doc Type
Permit Document
Status
Ready to Film
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
34
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
Activity Number: 555-20-004636-PRMT Date: July 13,20 <br /> Project Address: 9565 Elkhorn Woods Cir SE Lyons Kim Aldrich WWS <br /> 093E02DD00500 <br /> ONSITE WASTEWATER TREATMENT SYSTEM <br /> With SEEPAGE BED AND ATT TREATMENT <br /> A SEEPAGE BED is required for this system. The bed must consist of a 15*20 ft or a 300 ft2 gravel <br /> area at a depth of 24-30 inches. Please see attached map for approved area. The bed must contain drain <br /> media at least 12 inches deep with at least 6 inches of media under the pressure distribution laterals, and <br /> sufficient media above the laterals to meet or cover the orifice shields to provide a smooth, even cover. <br /> Pressurized distribution piping must be horizontally spaced not more than 4 feet apart and not more than <br /> 2 feet away from the walls of the seepage bed. The top of the drain media must be covered with filter <br /> fabric or other non-degradable material. There must be sweeps at the end of each line to allow for <br /> cleaning and maintenance. Lateral piping orifices will need to be drilled at 1/8 of an inch, and must be <br /> spaced at 24 inches apart. <br /> SERVICE CONTRACTS: The owner of an ATT system and a seepage bed per OAR 340 must <br /> maintain a service contract with a maintenance provider certified by the manufacturer to service and <br /> maintain the onsite system. A service contract must be entered into before the permit is issued and must <br /> be maintained until the system is decommissioned. The service contract must provide for a minimum of <br /> four inspections and service visits by a maintenance provider scheduled once every six months over a <br /> two-year period to inspect, adjust, and service the ATT. The maintenance provider must submit an <br /> annual report and fee. Please review OAR 340-071-0345 for full requirements. <br /> AN EFFLUENT LIFT PUMP WILL BE REQUIRED to install the septic system disposal field in the <br /> approved area and at the required depth. Detailed instructions for dosing tank/effluent pump installations <br /> are available in our office. The electrical wiring to the pump and alarm must be installed in accordance <br /> with the appropriate Electrical Code. The electrical work must be done under a Marion County Electrical <br /> Permit and must be inspected and approved by a Marion County Electrical Inspector. The work must be <br /> left uncovered and accessible for inspection. The electrical inspection includes the connections to the <br /> pump and alarm in the dosing tank,the wiring in the trench and the connections in the structure. <br /> Please provide an installation plot plan, an operation and maintenance agreement and a materials list so <br /> that an installation repair permit can be issued. <br /> 5155 Silverton Road NE—P.O.Box 14500--Salem,Oregon 97309-5036—Phone(503)588-5147—Fax(503)588-7948 <br />
The URL can be used to link to this page
Your browser does not support the video tag.