Laserfiche WebLink
Waite Concrete Products, LLC <br /> Anti-buoyancy: 3000 Gallon Tank <br /> Minimum Cover-24" <br /> The following is a list of methods that may be used, as additional <br /> precautions, to insure tank submergence in area with high ground water. <br /> 1. Require a minimum cover of 24" where there is high groundwater. <br /> 2. After setting the tank, pour an additional thickness of concrete over the <br /> tank top 3" minimum extending a minimum of 12" beyond the sides of <br /> .�., the tank. <br /> 3. Concrete buoyancy blocks secured with stainless steel cables placed. <br /> over tank. <br /> Calculations,in feet: Tank: Cover: <br /> Length 12.50 12.50 <br /> Width 7.17 7.17 <br /> Height 7.33 2.00 <br /> Volume 656.94 205.30 <br /> Water Weight (lb) 41011 <br /> Tank Weight (lb) 24260 <br /> Weight to Balance (Ib). 17011 <br /> Weight to Cover (lb) 17302 <br /> Density: Or- <br /> cl;: <br /> 62.43 Water (Ib/ft3) Cbv Le)-'11 ,gyp )A' <br /> 1.35 Soil Factor (typical bulk density) •N'° <br /> 84.28 Soil (lb/ft3) �•,L <br /> 2.21 Concrete Factor �I i51,L2 <br /> 8.24 Concrete (Ib/ft3) <br />