Permit Address
9308 SILVER FALLS HWY SE
Permit City
Aumsville
Permit Number
555-20-008588-PRMT-01
Parcel Number
082W13DA01400
Permit Type
Septic
Permit Doc Type
Permit Document
Status
Ready to Film
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
42
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
Onsite Permit 555-20-008588-PRMT-01 Page 2 of 3 <br /> Schedule or track inspections at www.buildingpermits.oregon.gov <br /> Call or text the word "schedule"to 1-888-299-2821 use NR Number:555052206909 <br /> Schedule using the Oregon ePermitting Inspection App, search"epermitting"in the app store <br /> bate issued t/1`.0/214,2 x ; W -7 .. *' s` ,��t - 4 •gJ , 613: aicif•tlata,gi t�/ <br /> S y rogrk lttnet7 "p .f�oo b'°i�'.� '' w _-u Y ` y )4`.. , e. � �.' i-. 1' yh itf.- a'+? �'' <br /> `Mt*)le1cri040:, AiYREP REBtU LD4cBORM! E6i,PAM ,'GED Y FI E . - . � ,. � <br /> Iry ;0.. :t', it ,.3;r ASH' ; ,..2,4, • k .:t,,' ,*f .ru': . ;A"I'? ,.. e .:7. <br /> Special Requirements <br /> Groundwater type: Permanent Groundwater depth: 12 in. <br /> Pump to drainfield reqd: Yes Filter fabric on top of drain media: N/A <br /> Other special rqmt: read all conditions of approval <br /> Conditions of approval <br /> -This repair permit is for replacement of the existing septic system,following a house fire in late 2020.An <br /> authorization notice was applied for and could not be approved.The existing system was less than 5'from the <br /> stream and was dyed using tracer dye on December 7,2020 by Marion County Onsite Wastewater Staff.The <br /> tracer dye showed that the system discharges to the adjacent creek.The authorization could not be issued and <br /> a repair permit was required per OAR 340-071-0205(4)(a). • <br /> •This property appears to consist of two separate legal lots of record.Based on the field stakeout inspected by <br /> Marion County Onsite Wastewater Staff the entire onsite wastewater treatment system fits within the southern, <br /> 50'wide lot.The property lines must be marked by a Professional Land Surveyor prior to installation and <br /> inspection to ensure the system does not cross any real property lines. <br /> Properly decommission the old septic tank and submit appropriate documentation. <br /> •This permit is for the installation of an Alternative Treatment Technology(ATT)system and is to be installed <br /> by a person certified by the system manufacturer in accordance with OAR 340-071-0600 and 0650.See <br /> Alternative Treatment Technology rules at OAR 340-071-0345. <br /> •ATT treatment standard 2 required. <br /> -Vehicular traffic and livestock must be restricted from the system area. <br /> •All tanks must be tested for watertightness and have a water-tight riser to the ground surface.Twenty-inch <br /> minimum diameter if less than 36-in deep.Thirty-inch minimum diameter if greater than 36-in deep.Maintain <br /> access to septic tank for pumping and service. <br /> The pump and alarm must be wired on separate circuits in the control panel.Pump wiring must comply with <br /> applicable building,electrical,or other codes.An electrical permit and inspection from the Department of <br /> Consumer and Business Services,Building Codes Division,or the municipality with jurisdiction, is required for <br /> pump wiring installation. <br /> -An anti-buoyancy device is required for the septic tank(s)and must be installed as per the manufacturer <br /> installation guidelines. <br /> -Graveness absorption method rules at OAR 340-071-0290(6).Pressurized distribution required w/ <br /> distribution piping perforated with 1/8 inch diameter orifices on maximum 2-foot centers at the 12 o'clock <br /> position and at least a 2-foot residual head at the distal orifice. <br /> 5/10/21:11:17:24AM Page 2 of 3 ONS_OnsitePermit,pr <br />
The URL can be used to link to this page
Your browser does not support the video tag.