Laserfiche WebLink
Septic Permit 555-22-001787-PRMT Page 2 of 3 <br /> 3 p m Y E ^�w-�� Y�Y �' E ,k 9r <br /> ate$+ fat rgitita t it8/2621 kho � �� <br /> rC rsr �:v T:° F y 3 �c a `�`� � �F i c 4 <br /> •7t 1� 1i1 F ii F iViAs7 RE BORMl a �, .f'�ycE y�°' .�s � i w+�'' I6 'r � E�.+' ,,"fig h a,�,y;, ,,`��,,'t ,. <br /> � �s�i� ��%'�er w3 '� ��� a, "m: aaya�, vss to ., ✓ �/'Ks9 rfnt'.�y ,{���y��• ': « s v .m .�i, <br /> f .h,i' ii"!i Sc,'�F' d"bir.'.?, �� ,. �'t ,'��.�,.. E €, �'�1✓onjii. •b,4,A^Pj rQ u3�4sb ("�: <br /> •This repair permit is for replacement of the existing septic system following the Lionshead Fire of 2020 which burned this <br /> property. <br /> •Properly decommission the old septic tank and submit appropriate documentation. <br /> Pressurized distribution rules at OAR 340-071-0275. Install sweep elbows at ends of lateral piping with acceptable threaded <br /> plugs or caps.Minimum head of 5-ft at remotest orifice,less than 10%variation. <br /> •Dry soil installation only(June 1 —October 1 unless otherwise authorized by the agent). <br /> •The system must be installed by the property owner or a licensed sewage disposal business(installer). <br /> •Vehicular traffic and livestock must be restricted from the system area. <br /> •All roof drains must be directed away from the system <br /> •All tanks must be tested for watertightness and have a water-tight riser to the ground surface.Twenty-inch minimum diameter if <br /> less than 36-in deep.Thirty-inch minimum diameter if greater than 36-in deep. Maintain access to septic tank for pumping and <br /> service. <br /> •Meet all required setbacks <br /> •The system must be installed in the area approved during the site evaluation and in accordance with the construction plan <br /> approved by the agent,including any changes made by the agent. <br /> •The pump and alarm must be wired on separate circuits in the control panel. Pump wiring must comply with applicable building, <br /> electrical,or other codes.An electrical permit and inspection from the Department of Consumer and Business Services, Building <br /> Codes Division,or the municipality with jurisdiction,is required for pump wiring installation. <br /> •Install the pump and system components in accordance with the approved pump curve and specifications. <br /> •An anti-buoyancy device is required for the septic tank(s)and must be installed as per the manufacturer installation guidelines. <br /> •A minimum 18-gauge,green-jacketed tracer wire or green color-coded metallic tape must be placed on top of the effluent sewer <br /> or pressure transport pipe from tank to drainfield. <br /> Installation of this onsite wastewater treatment system has been determined to comply with the applicable requirements in <br /> Oregon Administrative Rules Chapter 340, Divisions 071 and 073 and the Conditions of Approval above. <br /> 1.In accordance with Oregon Revised Statute 454,665,this Certificate of Satisfactory Completion is issued as evidence of <br /> satisfactory completion of an onsite wastewater treatment system at the location identified above. <br /> 2. Issuance of this Certificate does not constitute a warranty or guarantee that this onsite wastewater treatment system will <br /> function indefinitely without failure.Conditions imposed as permit requirements continue for the life of the system. <br /> 3.The area of the initial and the identified replacement area must not be subjected to activity that is likely to adversely affect <br /> the soil or the functioning of the system.Such activities may include, but are not limited to,vehicular traffic, livestock, <br /> covering the area with asphalt or concrete,filling,cutting,or other soil modification activities. <br /> 4.This onsite wastewater treatment system that be connected to the facility referenced herein within 5 years of the issuance <br /> of this Certificate of Satisfactory Completion(CSC)or rules for authorization notices,alteration permits,or <br /> construction-installation permits as outlined in OAR 340-071-0160,340-071-0205,or 340-071-0210 apply, including payment <br /> of an additional fee. <br /> 5.This system must operate in compliance with OAR Chapter 340, Division 071 and must not create a public health hazard <br /> or pollute public waters. <br /> 6.Unless otherwise required by the agent,the system installer must backfill(cover)this system within 10 days after the <br /> issuance of this Certificate of Satisfactory Completion. <br /> 8/18/23:9:23:29AM ONS_OnsiteCSCjr <br />