Laserfiche WebLink
Onsite Permit 555-21-010382-PRMT Page 2 of 3 <br /> Schedule or track inspections at www.buildingpermits.oregon.gov <br /> Call or text the word "schedule" to 1-888-299-2821 use IVR Number:555079721444 <br /> Schedule using the Oregon ePermitting Inspection App, search"epermitting"in the app store <br /> �- 1 <br /> Date issued 1 13/2 f � <br /> Work <br /> d eacripta, nFIR A E RE PAIR RE BDq RM� rcR WITHc NS FDD3IB DRM.I Sx M OOTP RINi <br /> „Awl k9`* P. r <br /> , a �� •'� Cf i � y��` <br /> Special Requirements <br /> Stake out required: No <br /> Groundwater type: Permanent Groundwater depth: N/A <br /> Pump to drainfield reqd: Yes Filter fabric on top of drain media: Yes <br /> Other special rqmt: Sweeps must be installed at the end of each pressure line <br /> STAKEOUT ALREADY PERFORMED OK FOR INSTALL <br /> Conditions of approval <br /> •An electrical permit and inspection from the Department of Consumer and Business Services, <br /> Building Codes Division,or the municipality with jurisdiction,is required for pump wiring installation. <br /> •The owner of a pressurized distribution system must maintain a contract with a certified <br /> maintenance provider to inspect,adjust and maintain the onsite system.The maintenance provider <br /> must submit an annual report and annual evaluation fee. <br /> •Pressurized distribution rules at OAR 340-071-0275.Install sweep elbows at ends of lateral piping with <br /> acceptable threaded plugs or caps.Minimum head of 5-ft at remotest orifice,less than 10%variation. <br /> •The system must be installed by the property owner or a licensed sewage disposal business(installer). <br /> •Vehicular traffic and livestock must be restricted from the system area. <br /> •All roof drains must be directed away from the system <br /> Ali tanks must be tested for watertightness and have a water-tight riser to the ground surface.Twenty-inch <br /> minimum diameter if less than 36-in deep.Thirty-inch minimum diameter if greater than 36-in deep.Maintain <br /> access to septic tank for pumping and service. <br /> •Meet all required setbacks <br /> •The system must be installed in the area approved during the site evaluation and in accordance with the <br /> construction plan approved by the agent, including any changes made by the agent. <br /> •The pump and alarm must be wired on separate circuits in the control panel. Pump wiring must comply with <br /> applicable building,electrical,or other codes. <br /> •Install the pump and system components in accordance with the approved pump curve and specifications. <br /> •A minimum 18-gauge,green-jacketed tracer wire or green color-coded metallic tape must be placed on top of <br /> the effluent sewer or pressure transport pipe from tank to drainfield. <br /> •The seepage bed must be level within a tolerance of plus or minus 1-inch. <br /> •All work is to conform to OAR 340, Division 71 and 73.Make no changes in system location or specifications <br /> without approval by the agent. <br /> •For product approval information and manufacturer installation requirements see DEQ website at: <br /> http://www.oregon.govkleq/Residential/Pages/Onsite.aspx <br /> 11/3/21:9:23:46AM ONS_OnsitePermitjr <br />