Laserfiche WebLink
,, 361136 E <br /> ion III III ■ Ell ■■■■■■ ■■ ■■ III ■ ■■■■■ — q <br /> - ■■ ■ ■■■ III ■ ■ ■■ NO ■■ - 1 <br /> m ■■■ ■ ■ ■■■ ■■■■■ ■■ I ■■■ II — o <br /> AdvanTex Field Maintenance Report A&B SEPTIC S E RV I C E <br /> 6 Month Inspection (541) 924-0851 <br /> Property Owner/hacking# Operator <br /> J Eggert Mike S <br /> Site Address Contact Phone <br /> 9565 Elkhom Woods Cir SE Lyons <br /> AX Site ID# County ID# Pod# RTU#NL# Date of Last Inspection <br /> Retrieve O&M Info Measure Sludge/Scum <br /> Daily flow Sludge Scum <br /> 1st Compartment Current Previous Current Previous <br /> Recirc ratio 0 0 <br /> Timer settings: <br /> 2nd Compartment Current Previous Current Previous <br /> 0 0 <br /> Inspect/Clean AdvanTex Filter <br /> Inspect Clean <br /> Odor. 0 Normal ❑Pungent Laterals/Orifices 0 El <br /> Perform Field Sampling/Observations <br /> Biomat: 0 Normal ❑Excessive Pod Bottom El El <br /> NTU(15±NTUs) pH(6-9) DO(2-6) Bridging/Ponding: 0 None/Minor 0 Excessive Intake Vent 0 El <br /> 2.72 7 6 Inspect/Clean Discharge Pump System <br /> Odor of Sample Inspect Inspect Clean <br /> Typical El Musty 0 Earthy El Moldy <br /> Riser/Lid ElFloats � ❑ <br /> El <br /> Non-typical 0 Sulfide El Cabbage El Decay Splice Box Pump 0 <br /> 0 <br /> Oily film in PVU ['Yes El No Float cords <br /> Foam in tank ❑Yes El No Inspect/Service Other System Components <br /> Inspect Clean Inspect Clean <br /> Check Control Panel Disinfection Equipment 0 0 Dispersal Laterals/Orifices 0 El <br /> Recirc Amps Discharge Amps Observations <br /> 10.7 10.4 Additional Services Rendered <br /> 0 Cleaned textile sheets? ❑Replaced UV items? <br /> Audible and visual alarms El OK <br /> 0 Replaced/Used other items? <br /> Dial tone(telemetry only) ❑Yes 0 No <br /> Parts Used:W=Warranty,B=Billable(✓appropriate selection) <br /> Inspect/Clean Pump System w B Item Number Description <br /> Inspect Clean <br /> Riser/Lid 0 I - <br /> Splice Box 0 <br /> Float Cords El <br /> Floats ❑ ❑ Final/Safety Inspection <br /> Pump 0 0 0 RSV reinstalled 0 Lids bolted on <br /> Biotubee Filter 0 0 El Manifold reconnected;flush valves closed 0 Control panel reactivated <br /> Biotube Pump Vault 0 0 Summary/Recommendations <br /> Recirculating Splitter Valve 01:1 0 System performing;no further action needed 0 Tank needs pumping <br /> ❑Call for service ❑Other? <br /> Comments System operating correctly at time of service. <br /> Signature Date 6/1/23 <br /> Fax completed form to 1-866-384-7404 <br />