My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
11911972
Images9
>
Public Works - Permits
>
Building
>
FOR PUBLIC VIEW ON INTERNET
>
COMPLETED FILES - INACTIVE
>
21-XXXXXX
>
11911972
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/25/2023 8:00:14 PM
Creation date
10/25/2023 4:00:36 PM
Metadata
Fields
Template:
Permits
Permit Address
150 CLIFFORD AVE E
Permit City
Detroit
Permit Number
555-21-009740-PRMT-01
Parcel Number
105E01CA03000
Permit Type
Septic
Permit Doc Type
Permit Document
Status
Ready to Film
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
17
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
Septic Permit 555-2YY1-009740-PRMT-01 Page 2 of 3 <br /> 4.. 4 : <br /> Work i3escri tIan� � CRE MIIV REF�AIR TAR[K QNLY�REPL 2 i3t7R{UI /iTH�4 RDRM*SAME FQL�TPt IN a 4 <br /> 4 p _ � � ��,j �"� s oz, � �u� *, a 'fat� t �� �'` rty 0�� 4 <br /> r .... Canrlhtions <br /> •This repair permit is for the voluntary replacement of the septic tank following the Beachie Creek/Lionshead Fire of 2020 which <br /> burned this property.A 1500 gallon,two compartment septic tank with an effluent filter is required due to the proposed <br /> grinder/solids pump. <br /> 'Properly decommission the old septic tank and submit appropriate documentation. <br /> •All tanks must be tested for watertightness and have a water-tight riser to the ground surface.Twenty-inch minimum diameter if <br /> less than 36-in deep.Thirty-inch minimum diameter if greater than 36-in deep.Maintain access to septic tank for pumping and <br /> service. <br /> •A minimum 18-gauge,green-jacketed tracer wire or green color-coded metallic tape must be placed on top of the effluent sewer <br /> or pressure transport pipe from tank to drainfield. <br /> 'Effluent filter required at tank outlet. <br /> 'Effluent sewer.The effluent sewer must extend at least 5 feet beyond the septic tank before connecting to the distribution unit. It <br /> must be installed with a minimum fall of 4 inches per 100 feet and at least 2 inches of fall from one end of the pipe to the other. In <br /> addition,there must be a minimum difference of 8 inches between the invert of the septic tank outlet and either the invert of the <br /> header to the distribution pipe of the highest lateral in a serial distribution field or the invert of the header pipe to the distribution <br /> pipes of an equal distribution absorption field. <br /> Installation of this onsite wastewater treatment system has been determined to comply with the applicable requirements in <br /> Oregon Administrative Rules Chapter 340, Divisions 071 and 073 and the Conditions of Approval above. <br /> 1. In accordance with Oregon Revised Statute 454,665,this Certificate of Satisfactory Completion is issued as evidence of <br /> satisfactory completion of an onsite wastewater treatment system at the location identified above. <br /> 2. Issuance of this Certificate does not constitute a warranty or guarantee that this onsite wastewater treatment system will <br /> function indefinitely without failure.Conditions imposed as permit requirements continue for the life of the system. <br /> 3.The area of the initial and the identified replacement area must not be subjected to activity that is likely to adversely affect <br /> the soil or the functioning of the system.Such activities may include,but are not limited to,vehicular traffic, livestock, <br /> covering the area with asphalt or concrete,filling,cutting,or other soil modification activities. <br /> 4.This onsite wastewater treatment system that be connected to the facility referenced herein within 5 years of the issuance <br /> of this Certificate of Satisfactory Completion(CSC)or rules for authorization notices,alteration permits,or <br /> construction-installation permits as outlined in OAR 340-071-0160,340-071-0205,or 340-071-0210 apply,including payment <br /> of an additional fee. <br /> 5.This system must operate in compliance with OAR Chapter 340, Division 071 and must not create a public health hazard <br /> or pollute public waters. <br /> 6. Unless otherwise required by the agent,the system installer must backfill(cover)this system within 10 days after the <br /> issuance of this Certificate of Satisfactory Completion. <br /> 10/17/23:9:25:35AM ONS_OnsiteCSC_pr <br />
The URL can be used to link to this page
Your browser does not support the video tag.