Laserfiche WebLink
Onsite Permit 555-22-001573-PRMT Page 2 of 3 <br /> Schedule or track inspections at www.buildingpermits.oregon.gov <br /> Call or text the word "schedule" to 1-888-299-2821 use IVR Number:555045366424 <br /> Schedule using the Oregon ePermitting Inspection App, search"epermitting"in the app store <br /> Date issued: 2/23/22 Expiration date: 2/23/23 <br /> Work description: NEW ATT INSTALL FOR 3 BDRM SFD <br /> Max depth: 36 in. Undisturbed soil between trenches: 8 ft. <br /> Min depth: 30 in. Capping fills-min depth of fill material: N/A <br /> Special Requirements <br /> Pump to drainfield reqd: N/A Filter fabric on top of drain media: Yes <br /> Conditions of approval <br /> •The owner of an ATT system must maintain a contract with a maintenance provider certified by the <br /> manufacturer to inspect,adjust and maintain the onsite system.The maintenance provider must submit an annual <br /> report and annual evaluation fee. <br /> •In addition to the As-Built and Materials List,a Start-Up checklist from the ATT maintenance provider is <br /> required to Final this permit. <br /> •Dry soil installation only(June 1 —October 1 unless otherwise authorized by the agent). <br /> •The system must be installed by the property owner or a licensed sewage disposal business(installer). <br /> -Vehicular traffic and livestock must be restricted from the system area. <br /> •All tanks must be tested for watertightness and have a water-tight riser to the ground surface.Twenty-inch <br /> minimum diameter if less than 36-in deep.Thirty-inch minimum diameter if greater than 36-in deep. Maintain <br /> access to septic tank for pumping and service. <br /> •All roof drains must be directed away from the system <br /> •The system must be installed in the area approved during the site evaluation and in accordance with the <br /> construction plan approved by the agent, including any changes made by the agent. <br /> -All work is to conform to OAR 340, Division 71 and 73. Make no changes in system location or specifications <br /> without approval by the agent. <br /> •The pump and alarm must be wired on separate circuits in the control panel. Pump wiring must comply with <br /> applicable building,electrical,or other codes.An electrical permit and inspection from the Department of <br /> Consumer and Business Services, Building Codes Division, or the municipality with jurisdiction, is required for <br /> pump wiring installation. <br /> A minimum 18-gauge,green-jacketed tracer wire or green color-coded metallic tape must be placed on top of <br /> the effluent sewer or pressure transport pipe from tank to drainfield. <br /> •Header pipe from Distribution or Drop Box must be minimum 4-ft length, level, and bedded. <br /> •Each drainfield trench must be level within a tolerance of plus or minus 1-inch. <br /> -Serial distribution,each trench bottom to be level and on contour. Use Drop box(es). <br /> 2/23/22:2:32:19PM ONS_OnsitePermitjDr <br />