Laserfiche WebLink
Page 3 <br /> 1003T-GEO lowing a sand filter in lieu of the chamber described in OAR <br /> NATIVE BACKFILL ESTABLISH <br /> "MIN.COVER VEGETATIVE Chapter 340 Division 71. Construction shall conform to all <br /> COVER <br /> OR PER CODE requirements described within Chapter 340 Division 71 with <br /> the following modifications: <br /> 1111.111111 4" RFORATED <br /> 0 PIPEPE a. The perforated pressure piping shall be placed <br /> FILTER FABRIC within the 4-inch diameter perforated polyethylene <br /> 15" piping with orifices at the 12 o'clock position. <br /> ! , . <br /> , , 10"EZflow b. Because the top of the bundle will be at the <br /> 24"MIN. BUNDLE(TYP.) capping TRENCH ground round surface, a ca in fill shall be used <br /> WIDTH to cover the installation. Soil texture from the surface <br /> Figure 3 <br /> to the trench bottom shall not be finer than silty clay <br /> trench. For example, if the sizing for a 2-foot gravel trench loam. <br /> requires 100-linear feet of trench, the 1003T system will be <br /> sized at 100-linear feet. See the Oregon Chamber Design and Installation Manual for ad- <br /> ditional options and information. <br /> The Capping Fill System <br /> The 1201 P/1201 P-GEO Seepage Trench System <br /> The 1201 P-GEO drainfield system consists of one, 12-inch 10045/1004S-GEO, 1204S/1204S-GEO <br /> diameter bundle installed in a 12-inch wide trench. See figure Both the 10-inch and 12-inch diameter bundles may be in- <br /> 1 for example configuration. stalled in seepage trenches in lieu of drain media. Four or <br /> more bundles can be placed in a 24-inch wide trench.At least <br /> The 1202H one of the top bundles shall contain perforated piping. Serial <br /> The 1202H drainfield system may also be installed in a hori- distribution methods limit the maximum effluent depth to no <br /> zontal configuration in a capping fill system, within a 24-inch more than 6-inches higher than the invert level of the perfo- <br /> wide trench that is a minimum of 12-inches deep. See figure rated piping within the higher trenches.The minimum backfill <br /> 2 for example configuration. depth is 6-inches when equal distribution methods are used, <br /> and 12-inches with serial distribution methods. See Figure 5 <br /> The 1003T for example configuration. <br /> The 1003T drainfield system may also be installed in a cap- 1204S-GEO <br /> ping fill system. The 1003T in the horizontal configuration is <br /> A'�ESTAinstalled in a 30-inch wide trench that is a minimum of 12- VEGETATIVE <br /> VEGETATIVE COVER <br /> inches deep.The 1003T triangular configuration is installed in k, ,, „,,. + ,,,,, <br /> a 24-inch wide trench that is a minimum of 17- inches deep, NATIVE BACKFILL 6"MIN. FILTER FABRIC <br /> COVER OR PER CODE <br /> with the cap placed in accordance with the requirements of <br /> OAR Chapter 340 Division 71. See Figure 3 for example con- 4"PERFORATED PIPE <br /> figuration. 24" <br /> , 12"EZflow <br /> BUNDLE(TYP.) <br /> Conventional Sand Filter System Using Gravelless <br /> Absorption Trenches-The 1001 P/1001 P-GEO ' 24"MIN. <br /> The 1001 P/1001 P-GEO drainfield system (10-inch diameter TRENCH <br /> bundles containing 4-inch diameter perforated polyethylene WIDTH <br /> Figure 5 <br /> piping, placed end to end within the trench) may be used fol- <br /> 1001P-GEO - eep Slope Systems <br /> I00IA/1001A-GEO, 1001 P/1001 P-GEO <br /> NATIVE ESTABLISH 1201A/1201A-GEO, 1201 P/1201 P-GEO <br /> BACKFILL VEGETATIVE Both the 10-inchand 12-inch diameter bundlesbe <br /> CAPPING FILL COVER <br /> MIN. may <br /> used within seepage trenches in a steep slope system in <br /> FILTER FABRIC lieu of drain media. Four bundles can be placed in a 24-inch <br /> wide trench. At least one of the top bundles shall contain <br /> the perforated piping. Serial distribution methods limit the <br /> maximum effluent depth to no more than 6 inches higher <br /> 1f° 4"PERFORATED PIPE <br /> �;?1_: than the invert level of the perforated piping with the high- <br /> trenches. GEO product can only be used at the top of t.- <br /> ;,_,c;;t�_KL.. 10"EZflow <br /> 10"MIN. BUNDLE(TYP.) configuration. See Figure 5 for example configurati.-. <br /> TRENCH <br /> WIDTH <br /> Figure 4 <br /> Contact Infiltrator Systems'Technical Services Department for assistance at 1-800-221-4436 <br />