11996213
Images9
>
Public Works - Permits
>
Building
>
FOR PUBLIC VIEW ON INTERNET
>
COMPLETED FILES - INACTIVE
>
21-XXXXXX
>
11996213
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/18/2024 11:44:46 AM
Creation date
1/2/2024 10:16:14 AM
Metadata
Fields
Template:
Permits
Permit Address
105 1ST ST W
Permit City
Detroit
Permit Number
555-21-000401-PRMT
Parcel Number
105E02AD00500
Permit Type
Septic
Permit Doc Type
Permit Document
Status
Ready to Film
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
19
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
Onsite Permit 555-21-000401-PRMT Page 4 of 6 <br /> Schedule or track inspections at www.buildingpermits.oregon.gov <br /> Call or text the word "schedule" to 1-888-299-2821 use IVR Number:555089047468 <br /> Schedule using the Oregon ePermitting Inspection App, search"epermitting"in the app store <br /> Date issued:3/1/21 Expiration date: 3/1/22 <br /> Work description: FIRE-MAJ REP: 3 BDRM SFD <br /> Conditions of approval <br /> Approved Area&System Type <br /> A soils test pit and other site features were evaluaated on the property during the site visit on January 20,2021 <br /> Conditions observed during this site evaluation indicate that the area around the evaluated test holes is not <br /> capable of supporting a Standard septic system due to the following limitation: <br /> Limited space <br /> Under the conditions observed at the above address, a PRESSURIZED DISTRIBUTION seepage bed system <br /> this must be at least 15*20 ft for a minimum total of 300 square ft. The minimum depth of installation for this <br /> seepage bed is 18-36 A new 1500 gallon septic dosing tank with a pump and alarm will be needed.An <br /> operation and maintenance agreement will be required to issue a permit. <br /> A PLOT PLAN WITH ALL REQUIRED EXHIBITS AND MATERIALS LIST IS NEEDED TO ISSUE THIS <br /> PERMIT(SEE APPROVED AREA FIELD MAP).WHEN INFORMATION IS RECEIVED AN INSTALLATION <br /> PERMIT WILL BE ISSUED. <br /> An electrical permit is required and must be finalled for a system install is finalled. <br /> Install system disposal field in the approved area and at the required depth. Detailed instructions for dosing <br /> tank/effluent pump installations are available in our office.The electrical wiring to the pump and alarm must be <br /> installed in accordance with the appropriate Electrical Code.The electrical work must be done under a Marion <br /> County Electrical Permit and must be inspected and approved by a Marion County Electrical Inspector. The <br /> work must be left uncovered and accessible for inspection.The electrical <br /> Both the initial and replacement disposal areas are to be protected from traffic, livestock and farming activities, <br /> development or other potential disturbance of natural soil conditions. <br /> The area must not be subjected to excessive saturation due to, but not limited to, artificial drainage of ground <br /> surfaces, roads, driveways and building down spouts. <br /> This approval is given on the basis that the parcel described above will not be further partitioned or subdivided. <br /> Pressurized distribution rules at OAR 340-071-0275. Install sweep elbows at ends of lateral piping with <br /> acceptable threaded plugs or caps(minimum head of 5-ft at remotest orifice, less than 10%variation). <br /> Filter fabric required over drain media(site has rapidly draining soils). <br /> 3/1/21:11:35:37AM Page 4 of 6 ONS_OnsitePermit_pr <br />
The URL can be used to link to this page
Your browser does not support the video tag.