My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
11996473
Images9
>
Public Works - Permits
>
Building
>
FOR PUBLIC VIEW ON INTERNET
>
COMPLETED FILES - INACTIVE
>
22-XXXXXX
>
11996473
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/2/2024 8:00:24 PM
Creation date
1/2/2024 1:30:35 PM
Metadata
Fields
Template:
Permits
Permit Address
12443 SUMMIT LOOP SE
Permit City
Turner
Permit Number
555-22-000171-PRMT-01
Parcel Number
092W20D 00900
Permit Type
Septic
Permit Doc Type
Permit Document
Status
Ready to Film
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
37
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
Oregon Department of Environmental Quality <br /> * The septic tank material is: <br /> x Concrete <br /> Steel <br /> Plastic <br /> Fiberglass <br /> Other(explain) <br /> Unknown <br /> * Is the septic tank accessible? x Yes No <br /> * Septic tank volume in gallons 1,000 <br /> * Tank volume determined by:Check all that apply,add comments below as needed <br /> x Permit Records x Measured Stamped on Tank Other <br /> * Septic tank risers are at ground level Yes x No <br /> * Tank appears to be free from defects,leaking and signs of deterioration x Yes No <br /> If you answered"No,"please describe the condition of the septic tank below.For example, <br /> evidence of gas corrosion,cracks,leaks,etc. <br /> * Septic tank lid(s)is intact x Yes No <br /> * Septic tank baffles are intact: Inlet x Yes No Outlet x Yes No <br /> * Baffle material-Inlet Plastic x Concrete Metal <br /> Outlet Plastic X Concrete Metal <br /> * Effluent filter is present Yes x No <br /> * Effluent filter is free of debris Yes No x Not applicable <br /> * Liquid level in tank relative to invert of outlet x At Above Below <br /> If above or below invert outlet,please explain: <br /> * Scum layer 2 (inches) Sludge layer 6 (inches) <br /> * Scum and Sludge layer more than 35%of the total tank volume Yes x No <br /> Indicate where sludge measured from: Inlet Middle x Outlet <br /> * Additional comments: <br /> PERFORMED A 150 GALLON FLOW TEST WITH A FLOW METER. <br /> 4. Dosing tank/Pump Basin <br /> Dosing tanks use a pump to send effluent to a treatment unit or soil absorption field. <br /> * The septic system has a dosing tank Yes x No <br /> (If"No,"skip the rest of section 4) <br /> * At the time of this evaluation the power was on to test the pump(s): Yes No <br /> Page 3 of 8 <br />