My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
12014500
Images9
>
Public Works - Permits
>
Building
>
FOR PUBLIC VIEW ON INTERNET
>
COMPLETED FILES - INACTIVE
>
21-XXXXXX
>
12014500
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/25/2024 10:53:21 AM
Creation date
1/18/2024 1:47:41 PM
Metadata
Fields
Template:
Permits
Permit Address
33682 RAILROAD AVE SE
Permit City
Gates
Permit Number
555-21-003362-AUTH
Parcel Number
093E25DC03600
Permit Type
Authorization
Permit Doc Type
Permit Document
Status
Ready to Film
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
24
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
• <br /> Oregon Department of Environmental Quality <br /> * Dosing tank capacity 500 (gallons) <br /> * Tank volume determined by:Check all that apply,add comments below as needed. <br /> x Permit Records x Measured Stamped on Tank Other <br /> * Dosing tank material CONCRETE <br /> * Dosing tank appears to be watertight and in good condition x Yes No <br /> * Dosing tank lid is intact Yes x No <br /> * Electrical components are sealed and watertight x Yes No <br /> * Pump/siphon is functional x Yes No <br /> * Type of Pump x Demand dose Time dose <br /> * Pump control mechanism is functional(floats,pressure transducer) x Yes No <br /> * There is a high water alarm _ x Yes No <br /> * The high water alarm(audible and visual)is working Yes x No Not Applicable <br /> * Type of screen BIO FILTER <br /> * Screen is clean and free of debris x Yes Fig <br /> * Screen cleaned for this evaluation x Yes No <br /> * Scum/sludge present in Dosing tank x j Yes No <br /> * Scum layer 0 (inches) Sludge layer 3 (inches) <br /> * Additional Comments: <br /> NO WATER OR POWER AVAILABLE. USED GENERATOR TO TEST ELECTRICAL COMPONENTS.LID, RISER, DISCHARGE,AND <br /> ELECTRICAL ALL NEED REPLACED FOR THE DOSING TANK.SEE ATTACHED PICTURES <br /> 5. Soil absorption system <br /> The soil absorption system is a set of trenches that receives effluent from the septic tank and <br /> filters the effluent before it enters the groundwater. <br /> * The septic system has a soil absorption system xI Yes No Unknown <br /> * Was the soil absorption system part of the evaluation? x Yes No See note below <br /> If the soil absorption system was not evaluated,please explain below for example unable to locate,client did not <br /> authorize this part of the evaluation): <br /> * Absorption distribution Equal []Serial Pressure x Equal via pressure <br /> * Absorption lines construction material: <br /> x Gravel and pipe Chamber }Tile Polystyrene foam and pipe Other <br /> * Absorption distribution unit(s): dropbox hydrosplitter equal distribution box <br /> Intact Damaged x N/A <br /> * Absorption distribution unit(s)are free of debris or solids l Yes No x N/A <br /> Page 4 of 8 <br />
The URL can be used to link to this page
Your browser does not support the video tag.