My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
12022583
Images9
>
Public Works - Permits
>
Building
>
FOR PUBLIC VIEW ON INTERNET
>
COMPLETED FILES - INACTIVE
>
21-XXXXXX
>
12022583
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/29/2024 10:04:34 AM
Creation date
1/25/2024 3:47:23 PM
Metadata
Fields
Template:
Permits
Permit Address
35364 FRANCIS ST SE
Permit City
Lyons
Permit Number
555-21-003282-PRMT
Parcel Number
084E32BD01800
Permit Type
Septic
Permit Doc Type
Permit Document
Status
Ready to Film
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
31
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
Onsite Permit 555-21-003282-PRMT Page 2 of 3 <br /> Schedule or track inspections at www.buildingpermits.oregon.gov <br /> Call or text the word "schedule" to 1-888-299-2821 use IVR Number:555062598877 <br /> Schedule using the Oregon ePermitting Inspection App, search "epermitting"in the app store <br /> Date issued:6/28/21 . 4 O � f <br /> �� � ; ax ago <br /> kg. -00tvrf, <br /> Work description:FIRE-MAJ REP: 3 BDRM TO REPL 3 BDRM l0 t . <br /> f <br /> Min depth: 18 in. Capping fills-min depth of fill material: N/A <br /> Special Requirements <br /> Stake out required: No <br /> Pump to drainfield reqd: Yes Filter fabric on top of drain media: N/A <br /> Other special rqmt: Operation and Maintenance agreement required to final septic install <br /> Conditions of approval <br /> •Dry soil installation only(June 1 —October 1 unless otherwise authorized by the agent). <br /> •Pressurized distribution rules at OAR 340-071-0275. Install sweep elbows at ends of lateral <br /> piping with acceptable threaded plugs or caps. Minimum head of 5-ft at remotest orifice, less <br /> than 10%variation. <br /> •The owner of a pressurized distribution system must maintain a contract with a certified <br /> maintenance provider to inspect, adjust and maintain the onsite system.The maintenance <br /> provider must submit an annual report and annual evaluation fee. <br /> •A squirt test inspection of the pressurized piping system is required. <br /> •Dry soil installation only (June 1 —October 1 unless otherwise authorized by the agent). <br /> •The system must be installed by the property owner or a licensed sewage disposal <br /> business (installer). <br /> •Vehicular traffic and livestock must be restricted from the system area. <br /> •AII tanks must be tested for watertightness and have a water-tight riser to the ground <br /> surface.Twenty-inch minimum diameter if less than 36-in deep. Thirty-inch minimum <br /> diameter if greater than 36-in deep. Maintain access to septic tank for pumping and service. <br /> •Meet all required setbacks <br /> •All work is to conform to OAR 340, Division 71 and 73. Make no changes in system location <br /> or specifications without approval by the agent. <br /> •For product approval information and manufacturer installation requirements see DEQ <br /> website at: http://www.oregon.gov/deq/Residential/Pages/Onsite.aspx <br /> •The pump and alarm must be wired on separate circuits in the control panel. Pump wiring <br /> must comply with applicable building, electrical, or other codes. An electrical permit and <br /> inspection from the Department of Consumer and Business Services, Building Codes <br /> Division, or the municipality with jurisdiction, is required for pump wiring installation. <br /> *Install the pump and system components in accordance with the approved pump curve and <br /> specifications. <br /> 1/20/23:10:19:52AM ONS_OnsitePermitpr <br />
The URL can be used to link to this page
Your browser does not support the video tag.