Laserfiche WebLink
12'R@1 ) <br /> Onsite Permit 555-23-005790-PRMT �-=� Page 2 of 3 <br /> Schedule or track inspections at www.buildingpermits.oregon.gov <br /> Call or text the word "schedule" to 1-888-299-2821 use IVR Number:555027515288 <br /> Schedule using the Oregon ePermitting Inspection App, search"epermitting"in the app store <br /> i)ate Issued 312212i ` � x� E pttian date; /2 /2 <br /> of descrtptiorr 4,13DRMA-t0 PU 13 '" 1 <br /> 1-14 <br /> � .� 4£. - �< � �.�, .:s:F "xs..' ,�« •£r .»a.,.. , 's; a`9 <br /> At <br /> Media type: Rock/Pipe Media depth: 30 in. <br /> Trench length: 144 linear ft. Rock above pipe: 2 in. <br /> Total rock depth: 6 in. Rock below pipe: 24 in. <br /> Max depth: 42 in. Undisturbed soil between trenches: 8 ft. <br /> Min depth: 40 in. Capping fills-min depth of fill material: N/A <br /> Special Requirements <br /> Stake out required: Yes <br /> Groundwater type: Not Applicable Groundwater depth: N/A <br /> Pump to drainfield reqd: Yes Filter fabric on top of drain media: N/A <br /> Other special rqmt: Only 144 Linear feet of drainfield required, plans specify 170 <br /> Conditions of approval <br /> -This permit is fora new 1500 gallon combo tank and 170 feet of seepage trenches <br /> -Requires single owner easement or property line adjustment. <br /> •The existing chicken coop must be removed from the drainfield area,as it does not meet setbacks <br /> •If any existing drainfield lines are found during excavation,the intersection must be sealed with <br /> bentonite clay. <br /> •An electrical permit and inspection from the Department of Consumer and Business Services, <br /> Building Codes Division,or the municipality with jurisdiction,is required for pump wiring installation. <br /> -Dry soil installation only(June 1 —October 1 unless otherwise authorized by the agent). <br /> -The system must be installed by the property owner or a licensed sewage disposal business(installer). <br /> •Vehicular traffic and livestock must be restricted from the system area. <br /> -All roof drains must be directed away from the system <br /> •All tanks must be tested for watertightness and have a water-tight riser to the ground surface.Twenty-inch <br /> minimum diameter if less than 36-in deep.Thirty-inch minimum diameter if greater than 36-in deep.Maintain <br /> access to septic tank for pumping and service. <br /> •Meet all required setbacks <br /> •The system must be installed in the area approved during the site evaluation and in accordance with the <br /> construction plan approved by the agent, including any changes made by the agent. <br /> •All work is to conform to OAR 340,Division 71 and 73. Make no changes in system location or specifications <br /> without approval by the agent. <br /> •For product approval information and manufacturer installation requirements see DEQ website at: <br /> http://www.oregon.govkleq/Residential/Pages/Onsite.aspx <br /> -The pump and alarm must be wired on separate circuits in the control panel. Pump wiring must comply with <br /> applicable building,electrical,or other codes. <br /> •Install the pump and system components in accordance with the approved pump curve and specifications. <br /> •A minimum 18-gauge,green-jacketed tracer wire or green color-coded metallic tape must be placed on top of <br /> the effluent sewer or pressure transport pipe from tank to drainfield. <br /> -Header pipe from Distribution or Drop Box must be minimum 4-ft length,level,and bedded. <br /> •Each drainfield trench must be level within a tolerance of plus or minus 1-inch. <br /> -Maximum length of an individual trench is 150-feet. <br /> •Serial distribution,each trench bottom to be level and on contour.Use Drop box(es). <br /> 3/22/24:11:19:24AM ONS_OnsitePermit,Dr <br />