Laserfiche WebLink
Onsite Permit 555-23-007417-PRMT Page 3 of 4 <br /> Schedule or track inspections at www.buildingpermits.oregon.gov <br /> Call or text the word "schedule" to 1-888-299-2821 use IVR Number:555014575646 <br /> Schedule using the Oregon ePermitting Inspection App,search"epermitting"in the app store <br /> wed., / r t x4li:, <br /> ft [ IYf� ttai71;7 � yr, k . y �"� a .c y., �° �', <br /> z,_.�. -, _ -. -.. . - �_ :<, '=, �;�P,�,a.,=. .�.�� �� ..'����4 rz•.� „�.S �,�;d _ - .. _ .. .. ., ,�..�,..,Ham;§� <br /> 4`= <br /> Conditions of approval <br /> •This permit is for the installation of an Alternative Treatment Technology(ATT)system and is to be installed by <br /> a person certified by the system manufacturer in accordance with OAR 340-071-0600 and 0650.See Alternative <br /> Treatment Technology rules at OAR 340-071-0345. <br /> •ATT treatment standard 1 required. <br /> •The ATT system must be designed to prevent untreated waste from passing into the absorption field if the <br /> treatment system malfunctions. <br /> •The septic tank must be approved for use with the ATT system to be installed. <br /> •In addition to the As-Built and Materials List,a Start-Up checklist from the ATT maintenance provider is <br /> required to Final this permit. <br /> •The owner of an ATT system must maintain a contract with a maintenance provider certified by the <br /> manufacturer to inspect,adjust and maintain the onsite system.The maintenance provider must submit <br /> an annual report and annual evaluation fee. <br /> •Gravelless absorption method rules at OAR 340-071-0290(6). Pressurized distribution required w/distribution <br /> piping perforated with 1/8 inch diameter orifices on maximum 2-foot centers at the 12 o'clock position and at least <br /> a 2-foot residual head at the distal orifice. <br /> •Dry soil installation only(June 1 —October 1 unless otherwise authorized by the agent). <br /> •The system must be installed by the property owner or a licensed sewage disposal business(installer). <br /> •Vehicular traffic and livestock must be restricted from the system area. <br /> •AII roof drains must be directed away from the system <br /> •AII tanks must be tested for watertightness and have a water-tight riser to the ground surface.Twenty-inch <br /> minimum diameter if less than 36-in deep.Thirty-inch minimum diameter if greater than 36-in deep.Maintain <br /> access to septic tank for pumping and service. <br /> •Meet all required setbacks <br /> •The system must be installed in the area approved during the site evaluation and in accordance with the <br /> construction plan approved by the agent,including any changes made by the agent. <br /> •All work is to conform to OAR 340, Division 71 and 73. Make no changes in system location or specifications <br /> without approval by the agent. <br /> •For product approval information and manufacturer installation requirements see DEQ website at: <br /> http://www.oregon.govkleq/Residential/Pages/Onsite.aspx <br /> •The pump and alarm must be wired on separate circuits in the control panel. Pump wiring must <br /> comply with applicable building,electrical,or other codes.An electrical permit and inspection from <br /> the Department of Consumer and Business Services,Building Codes Division,or the municipality with <br /> jurisdiction,is required for pump wiring installation. <br /> •Install the pump and system components in accordance with the approved pump curve and specifications. <br /> •A minimum 18-gauge,green-jacketed tracer wire or green color-coded metallic tape must be placed on top of <br /> the effluent sewer or pressure transport pipe from tank to drainfield. <br /> •Maximum length of an individual trench is 150-feet. <br /> •Each drainfield trench must be level within a tolerance of plus or minus 1-inch. <br /> 4/30/24:3:02:04PM ONS_OnsitePermit_pr <br />