My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
12267777
Images9
>
Public Works - Permits
>
Building
>
FOR PUBLIC VIEW ON INTERNET
>
COMPLETED FILES - INACTIVE
>
20-XXXXXX
>
12267777
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/18/2024 9:45:29 AM
Creation date
7/16/2024 4:51:07 PM
Metadata
Fields
Template:
Permits
Permit Address
123 SORBIN AVE E
Permit City
Gates
Permit Number
555-20-009195-PRMT
Parcel Number
093E26CC01800
Permit Type
Septic
Permit Doc Type
Permit Document
Status
Ready to Film
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
37
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
Page2of3 <br /> Septic Permit 555-20-009195-PRMT <br /> W°rkaes :pt, /Ir REP•# 'BMA- AR 6 K <br /> ,..'� £" � � ' 4: my T, 1� rye d+ <br /> .<..j .xx. <br /> 7�L 9, 9 �3�97 {pAtt .e., } .... Axa�b+ + <br /> ,. i ..., .. <br /> .Both the initial and replacement disposal areas are to be protected from traffic, livestock and farming <br /> activities, development or other potential disturbance of natural soil conditions <br /> •The pump and alarm must be wired on separate circuits in the control panel. Pump wiring must comply with <br /> applicable building, electrical, or other codes.An electrical permit and inspection from the Department of <br /> Consumer and Business Services, Building Codes Division, or the municipality with jurisdiction, is <br /> required for pump wiring installation. <br /> -Install the pump and system components in accordance with the approved pump curve and specifications. <br /> •The area must not be subjected to excessive saturation due to, but not limited to, artificial drainage of ground <br /> surfaces, roads, driveways and building down spouts. <br /> •This approval is given on the basis that the parcel described above will not be further partitioned or subdivided. <br /> -Pressurized distribution rules at OAR 340-071-0275. Install sweep elbows at ends of lateral piping with acceptable <br /> threaded plugs or caps(minimum head of 5-ft at remotest orifice, less than 10%variation). <br /> -Filter fabric required over drain media (site has rapidly draining soils). <br /> •The owner of a pressurized distribution system must maintain a contract with a certified maintenance provider to <br /> inspect, adjust and maintain the onsite system. The maintenance provider must submit an annual report and annual <br /> evaluation fee. <br /> •Dry soil installation only(June 1 —October 1 unless otherwise authorized by the agent). <br /> •The system must be installed by the property owner or a licensed sewage disposal business (installer). <br /> •All tanks must be tested for water-tightness and have a water-tight riser to the ground surface.Twenty-inch <br /> minimum diameter if less than 36-in deep (thirty-inch minimum diameter if greater than 36-in deep). <br /> •Maintain access to septic tank for pumping and service <br /> •The system must be installed in the area approved during the site evaluation and in accordance with the <br /> construction plan approved by the agent, including any changes made by the agent. <br /> • All work is to conform to OAR 340, Division 71 and 73. Make no changes in system location or specifications <br /> without approval by the agent. <br /> •For product approval information and manufacturer installation requirements see DEQ website at: <br /> http://www.oregon.gov/deq/Residential/Pages/Onsite.aspx <br /> •A minimum 18-gauge, green jacketed tracer wire or green color-coded metallic tape must be placed on top of the <br /> effluent sewer or pressure transport pipe from tank to drainfield. <br /> -Sewage ejector(grinder) pump: septic tank must be two-compartment with an effluent filter. <br /> -Effluent sewer must extend at least 5 feet beyond the septic tank before connecting to the distribution unit. It must <br /> be installed with a minimum fall of 4 inches per 100 feet and at least 2 inches of fall from one end of the pipe to the <br /> other. In addition, there must be a minimum difference of 8 inches between the invert of the septic tank outlet and <br /> either the invert of the header to the distribution pipe of the highest lateral in a serial distribution field or the invert of <br /> the header pipe to the distribution pipes of an equal distribution absorption field <br /> 7/12/24:2:41:31PM ONS_OnsiteCSCJDr <br />
The URL can be used to link to this page
Your browser does not support the video tag.