My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
12271039
Images9
>
Public Works - Permits
>
Building
>
FOR PUBLIC VIEW ON INTERNET
>
COMPLETED FILES - INACTIVE
>
24-XXXXX
>
12271039
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/23/2024 11:39:24 AM
Creation date
7/18/2024 1:21:20 PM
Metadata
Fields
Template:
Permits
Permit Address
15013 FERN RIDGE RD SE
Permit City
Stayton
Permit Number
555-24-005020-AUTH
Parcel Number
091W12A 01100
Permit Type
Authorization
Permit Doc Type
Permit Document
Status
Ready to Film
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
13
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
Oregon Department of Environmental Quality <br /> • The septic tank material is: <br /> [] Concrete <br /> ❑ Steel <br /> ❑ Plastic <br /> ❑ Fiberglass <br /> C Other(explain) <br /> 0 Unknown <br /> • Is the septic tank accessible? ®Yes ❑No <br /> • Septic tank volume in gallons 1,000 <br /> • Tank volume determined by:Check all that apply,add comments below as needed <br /> ®Permit Records®Measured❑ Stamped on Tank❑Other <br /> • Septic tank risers are at ground level ❑Yes ®No 12" Deep <br /> • Tank appears to be free from defects,leaking and signs of deterioration❑Yes ®No <br /> If you answered"No,"please describe the condition of the septic tank below.For example, <br /> evidence of gas corrosion,cracks,leaks,etc. <br /> Tank appears to be in good condition other than roots infiltrating arounf the inlet baffle and on <br /> the side of the tank.They are not causing any issues at this time <br /> • Septic tank lid(s)is intact ®Yes ['No <br /> • Septic tank baffles are intact:Inlet ®Yes ❑No Outlet ®Yes ❑No <br /> • Baffle material-Inlet nPlastic r1Concrete 121Metal Outlet 17Plastic [Concrete [Metal <br /> Effluent filter is present ❑Yes No <br /> • Effluent filter is free of debris ❑Yes ❑No Not Applicable <br /> • Liquid level in tank relative to invert of outlet ['At ®Above ❑Below <br /> If above or below invert outlet,please explain: Tank was overfull <br /> • Scum layer 14 (inches) Sludge layer 8 (inches) <br /> • Scum and Sludge layer more than 35%of the total tank volume ®Yes ['No <br /> Indicate where sludge measured from: ❑Inlet []Middle ❑Outlet <br /> • Additional Comments: <br /> Tank was overdue to be pumped, recommend pumping tank every 4 years <br /> 4. Dosing tank/Pump Basin <br /> Dosing tanks use a pump to send effluent to a treatment unit or a soil absorption field. <br /> • The septic system has a dosing tank ['Yes No <br /> (If"No,"skip the rest of section 4) <br /> • At the time of this evaluation the power was on to test the pump(s):['Yes ❑No <br /> Page 3 of 8 <br />
The URL can be used to link to this page
Your browser does not support the video tag.