Laserfiche WebLink
Septic Permit 555-24-004380-PRMT Page 2 of 2 <br /> fe�L%tttflCafe GSstted07fit10d � �T <br /> r <br /> ; -*Tr' <br /> S1AzIU11EUNFa <br /> •The system must be installed by the property owner or a licensed sewage disposal business(installer). <br /> -Vehicular traffic and livestock must be restricted from the system area. <br /> Alt roof drains must be directed away from the system <br /> •All tanks must be tested for watertightness and have a water-tight riser to the ground surface.Twenty-inch minimum diameter if less than 36-in deep. <br /> Thirty-inch minimum diameter if greater than 36-in deep.Maintain access to septic tank for pumping and service. <br /> .Meet all required setbacks <br /> •AII work is to conform to OAR 340,Division 71 and 73.Make no changes in system location or specifications without approval by the agent. <br /> for product approval information and manufacturer installation requirements see DEQ website at: <br /> http://www.oregon.gov/deq/Residential/Pages/Onsite.aspx <br /> •An anti-buoyancy device is required for the septic tank(s)and must be installed as per the manufacturer installation guidelines. <br /> •A minimum 18-gauge,green jacketed tracer wire or green color-coded metallic tape must be placed on top of the effluent sewer or pressure transport <br /> pipe from tank to drainfield. <br /> -Effluent sewer.The effluent sewer must extend at least 5 feet beyond the septic tank before connecting to the distribution unit.It must be installed with a <br /> minimum fall of 4 inches per 100 feet and at least 2 inches of fall from one end of the pipe to the other.In addition,there must be a minimum difference of 8 <br /> inches between the invert of the septic tank outlet and either the invert of the header to the distribution pipe of the highest lateral in a serial distribution field <br /> or the invert of the header pipe to the distribution pipes of an equal distribution absorption field. <br /> •Property decommission the old septic tank and submit appropriate documentation. <br /> Installation of this onsite wastewater treatment system has been determined to comply with the applicable requirements in <br /> Oregon Administrative Rules Chapter 340, Divisions 071 and 073 and the Conditions of Approval above. <br /> 1. In accordance with Oregon Revised Statute 454,665,this Certificate of Satisfactory Completion is issued as evidence of <br /> satisfactory completion of an onsite wastewater treatment system at the location identified above. <br /> 2.Issuance of this Certificate does not constitute a warranty or guarantee that this onsite wastewater treatment system will <br /> function indefinitely without failure.Conditions imposed as permit requirements continue for the life of the system. <br /> 3.The area of the initial and the identified replacement area must not be subjected to activity that is likely to adversely affect <br /> the soil or the functioning of the system.Such activities may include,but are not limited to,vehicular traffic, livestock, <br /> covering the area with asphalt or concrete,filling,cutting,or other soil modification activities. <br /> 4.This onsite wastewater treatment system that be connected to the facility referenced herein within 5 years of the issuance <br /> of this Certificate of Satisfactory Completion(CSC)or rules for authorization notices,alteration permits,or <br /> construction-installation permits as outlined in OAR 340-071-0160,340-071-0205,or 340-071-0210 apply, including payment <br /> of an additional fee. <br /> 5.This system must operate in compliance with OAR Chapter 340, Division 071 and must not create a public health hazard <br /> or pollute public waters. <br /> 6.Unless otherwise required by the agent,the system installer must backfill(cover)this system within 10 days after the <br /> issuance of this Certificate of Satisfactory Completion. <br /> r �.'. ,� � _��s�,�rSa� w �, �ai^R.,,�z�`�� y�#��€�j �i'j"` }�°fro' "���jF.: <br /> F ' 6- k ; Y eaiie t a y +aa �E.`/ � 'S 6l`.'? as <br /> ».. _0_01,`, »k- _Ar s..n„ 3..a.,. ,tmka�,,,oar,rem.r..;ti'.«.m �.xm+z a.max ..o as • �Y,�„s. s ,ym..4 ;a... . <br /> System Inspection: Yes Operation of Law-7 Days Notice: No Pre-Cover Inspection Waived Per 340-071: No <br /> Comments: COSC Issued <br /> a ,moo ,- € r '"' 5 "`` ;�,x°`w' 3 " "A .s `z - ;a <br /> t¢ � t ''� tea, � �.: 1 <br /> ..�w`,vCrCIclE,rv,.�pi.�k� '.��,.. t ., __ s , _ e s M <br /> Inspector Inspection Inspection Date Inspection Result <br /> Danielle Brown 7999 Final Septic 07/17/2024 Approved <br /> Matt Knudsen 7100 Septic Tank 07/02/2024 Approved <br /> Issued By: Kimberlee Aldrich, Onsite Wastewater Specialist 2 Effective Date: 07/17/2024 <br /> Ki.wt.h•e-f-Le e.ALd ritAA. <br /> CALL BEFORE YOU DIG...IT'S THE LAW <br /> ATTENTION:Oregon law requires you to follow rules adopted by the Oregon Utility Notification Center. Those rules are set forth by Oregon Administration Rules. You may obtain <br /> copies of the rules by calling the center.(Note:The telephone number for the Oregon Utility Notification Center is 1-800-332-2344.) <br /> 7/17/24:9:19:41AM ONS_OnsiteCSC_pr <br />