Laserfiche WebLink
Septic Permit 555-24-003361-PRMT Page 2 of 3 <br /> :s'��a <br /> �, <br /> a2c�? wrra `°� 'i�a <br /> vAlly�,; € as : <br /> #t '� r - "' 'a -.x . .6 ° "'I` ,« e *fix ,fit ' <br /> s <br /> _b � tomSk-k ,, ': `",. ,'' s Q[SEIt t� +' F .,k ..rs�•.. :' ,. . . `. w a °' .°a...,'�«,cp .., <br /> •Dry soil installation only(June 1 —October 1 unless otherwise authorized by the agent). <br /> •The system must be installed by the property owner or a licensed sewage disposal business(installer). <br /> .Vehicular traffic and livestock must be restricted from the system area. <br /> ▪All roof drains must be directed away from the system <br /> ▪All tanks must be tested for watertightness and have a water-tight riser to the ground surface.Twenty-inch minimum <br /> diameter if less than 36-in deep.Thirty-inch minimum diameter if greater than 36-in deep.Maintain access to septic <br /> tank for pumping and service. <br /> •Meet all required setbacks <br /> •The system must be installed in the area approved during the site evaluation and in accordance with the <br /> construction plan approved by the agent,including any changes made by the agent. <br /> •All work is to conform to OAR 340,Division 71 and 73.Make no changes in system location or specifications without <br /> approval by the agent. <br /> •For product approval information and manufacturer installation requirements see DEQ website at: <br /> hftp://www.oregon.govideq/Residential/Pages/Onsite.aspx <br /> ▪Effluent sewer.The effluent sewer must extend at least 5 feet beyond the septic tank before connecting to the <br /> distribution unit.It must be installed with a minimum fall of 4 inches per 100 feet and at least 2 inches of fall from one <br /> end of the pipe to the other.In addition,there must be a minimum difference of 8 inches between the invert of the <br /> septic tank outlet and either the invert of the header to the distribution pipe of the highest lateral in a serial distribution <br /> field or the invert of the header pipe to the distribution pipes of an equal distribution absorption field. <br /> •Header pipe from Distribution or Drop Box must be minimum 4-ft length,level,and bedded. <br /> •Each drainfield trench must be level within a tolerance of plus or minus 1-inch. <br /> •Serial distribution,each trench bottom to be level and on contour.Use Drop box(es). <br /> Installation of this onsite wastewater treatment system has been determined to comply with the applicable requirements in <br /> Oregon Administrative Rules Chapter 340, Divisions 071 and 073 and the Conditions of Approval above. <br /> 1. In accordance with Oregon Revised Statute 454,665,this Certificate of Satisfactory Completion is issued as evidence of <br /> satisfactory completion of an onsite wastewater treatment system at the location identified above. <br /> 2. Issuance of this Certificate does not constitute a warranty or guarantee that this onsite wastewater treatment system will <br /> function indefinitely without failure.Conditions imposed as permit requirements continue for the life of the system. <br /> 3.The area of the initial and the identified replacement area must not be subjected to activity that is likely to adversely affect <br /> the soil or the functioning of the system.Such activities may include,but are not limited to,vehicular traffic, livestock, <br /> covering the area with asphalt or concrete,filling, cutting,or other soil modification activities. <br /> 4.This onsite wastewater treatment system that be connected to the facility referenced herein within 5 years of the issuance <br /> of this Certificate of Satisfactory Completion(CSC)or rules for authorization notices,alteration permits,or <br /> construction-installation permits as outlined in OAR 340-071-0160,340-071-0205,or 340-071-0210 apply, including payment <br /> of an additional fee. <br /> 5.This system must operate in compliance with OAR Chapter 340, Division 071 and must not create a public health hazard <br /> or pollute public waters. <br /> 6. Unless otherwise required by the agent,the system installer must backfill(cover)this system within 10 days after the <br /> issuance of this Certificate of Satisfactory Completion. <br /> Y$ srii,C4,,C •Cs4t1 t�E� " y .,,*q: F . '16; .v ,,,'t' <br /> System Inspection: Yes Operation of Law-7 Days Notice: No Pre-Cover Inspection Waived Per 340-071: No <br /> Comments: COSC Issued <br /> s: rtzetLC rG ., Q4 ,o-;,0 .1�1 <br /> oilf <br /> Inspector Inspection Inspection Date Inspection Result <br /> Danielle Brown 7999 Final Septic 07/18/2024 Approved <br /> Danielle Brown 7999 Final Septic 07/12/2024 Partial <br /> 7/18/24:8:23:39AM ONS_OnsiteCSC_pr <br />