Laserfiche WebLink
Onsite Permit 555-24-005104-PRMT Page 2 of 3 <br /> Schedule or track inspections at www.buildingpermits.oregon.gov <br /> Call or text the word "schedule" to 1-888-299-2821 use IVR Number:555081817988 <br /> • <br /> Schedule using the Oregon ePermitting Inspection App, search"epermitting"in the app store <br /> w c� a s sa s ; " 4 ,caw <br /> DateFissued r/i r/24� :n ' -, peation da �' 117/25 <br /> Il1fo descri lion MAC f.EP„>~oR,33DRM e v 4-* w *' a, - 84. <br /> x4 �. a �' ✓a .N s '� s.;/; .<a s aaE«: +j. "^` '', off, g a s ,,;"*`• r cte <br /> • <br /> Total rock depth: 12 in. Rock below pipe: 6 in. <br /> Max depth: 26 in. Undisturbed soil between trenches: 8 ft. <br /> Min depth: 24 in. Capping fills-min depth of fill material: N/A <br /> Special Requirements <br /> Stake out required: Yes <br /> Groundwater type: Temporary Groundwater depth: 28 in. <br /> Pump to drainfield reqd: N/A Filter fabric on top of drain media: Yes <br /> Other special rqmt: An electrical permit must be finaled prior to issuance of the Certificate of Satisfactory Completion <br /> Conditions of approval <br /> •Dry soil installation only(June 1 —October 1 unless otherwise authorized by the agent). <br /> •The system must be installed by the property owner or a licensed sewage disposal business <br /> (installer). <br /> •Vehicular traffic and livestock must be restricted from the system area. <br /> •All roof drains must be directed away from the system <br /> •All tanks must be tested for watertightness and have a water-tight riser to the ground surface.Twenty-inch <br /> minimum diameter if less than 36-in deep.Thirty-inch minimum diameter if greater than 36-in deep.Maintain <br /> access to septic tank for pumping and service. <br /> •Meet all required setbacks <br /> •The system must be installed in the area approved during the site evaluation and in accordance with the <br /> construction plan approved by the agent, including any changes made by the agent. <br /> •All work is to conform to OAR 340, Division 71 and 73. Make no changes in system location or specifications <br /> without approval by the agent. <br /> •For product approval information and manufacturer installation requirements see DEQ website at: <br /> http://www.oregon.gov/deq/Residential/Pages/Onsite.aspx <br /> •The pump and alarm must be wired on separate circuits in the control panel. Pump wiring must comply with <br /> applicable building,electrical,or other codes.An electrical permit and inspection from the Department of <br /> Consumer and Business Services,Building Codes Division,or the municipality with jurisdiction,is required for <br /> pump wiring installation. <br /> •Install the pump and system components in accordance with the approved pump curve and specifications. <br /> •A minimum 18-gauge,green-jacketed tracer wire or green color-coded metallic tape must be placed on top of <br /> the effluent sewer or pressure transport pipe from tank to drainfield. <br /> -Header pipe from Distribution or Drop Box must be minimum 4-ft length,level,and bedded. <br /> .Each drainfield trench must be level within a tolerance of plus or minus 1-inch. <br /> •Maximum length of an individual trench is 150-feet. <br /> •Serial distribution,each trench bottom to be level and on contour.Use Drop box(es). <br /> 7/17/24:3:25:47PM ONS OnsitePermitpr <br />