AX-FAT Start-Up Checklist <br /> Service Provider e Ji, lit <br /> Q'icxr Ip— 1=ZOZ3Tcian Start-Up Date Occupancy Date <br /> Primary'treatment Other System Components <br /> Septic Tank. ❑ Disinfection system operating(tf installed). <br /> ❑ Indicate model of Blotube®filter installed In septic tank: V Dispersal.equip mentoperating. <br /> El FT0822-148(base inlet model)" <br /> R-FTSO444-36V(Schedule-40:outlet pipe) _ - <br /> Controls <br /> ❑ FTW0444-36V(Type 3034 outlet pipe) tglProper timer settings per p g Appendix 1 in AdvanTexO&M°Manua! <br /> ►.q,"Biotube,filter installed correctly on the septic tank outlet. <br /> Port 1,AIR-OM-AM-1 <br /> �4 At grade.access to Biotube filter. •Proper wire size used per Orenca Wire Tables;NCH-PU-PU-3. <br /> N Riser lid secured to the septic tank access riser. Panel wired per manufacturer's wiring diagram. <br /> All electrical connections in panel secured. <br /> Secondary'ireatment Control panel functronal.test,as detailed.In the AdvanTex <br /> Installation Instructions,has been followed. <br /> AXzg Unit 111 Dial.tone verified.(ForVCOM panels only.) <br /> Ix Transport line,has a minimum fall of Vs in.per foot(10 mm perm) <br /> S <br /> from septic tank to AX RlService provider name/number:written on"For Service Call"label, <br /> AX-RT unit installed level and;on a stable base. Centro!panel diagrams left in panel for future review. <br /> Unit is installed in series with or'perpendicular to septic tank,or <br /> Final/Safety inspection <br /> Unit:is installed with correct minimum offset from septic tank p. <br /> (if Installed parallel to tank): .All access riser hardware is.in pike.Lids are secured: <br /> ❑ 4 ft(1.2 m).offset(when no antibuoyancy measures are used). All splice box lids are secured. <br /> El '6 ft(1',8.m)offset(when'antibuayancy measures are:used). panel circuit breakers are In the°on°position,panel is set for <br /> All piping'properly covered and compacted. automatic.operation,and panel is latched(or locked if necessary). <br /> Ventilation System <br /> Passive air.vent line has minimum 1/a in:per foot:(1:0 mm per meted ItOmeOWnler'$ Package <br /> fall toAX-Ri. 4 .Homeowner's:Package reviewed With homeowner. <br /> jg Passive air vent on/iX-AT unit is Installed. <br /> Retire.Pumping,System Comments <br /> ..NFloats operate.. <br /> Pump operates in'Manual." <br /> Pump operates in"Automatic." <br /> Pump run amps: <br /> NI Pump rest:volts:. run Volts: `CSC .t <br /> AX- Manifold and Spin Nozzle Operation <br /> Manifold end cap closed,. <br /> Complete,square spray pattern with full coverage of sheets. <br /> ❑ Manifold pressure: <br /> (Typically 3:0-3.5 psi or20.7-24.1 kPa.) <br /> Discharge Pumping System(pump discharge only) <br /> / Floats operate. <br /> 151 Pump discharge plumbing connected. <br /> `2 °Off°float adjusted far correct discharge dose to dispersal. <br /> ©;2011 CrencoSysfems®Inc. SCL-ATX AX iT-OM-1 <br /> Rev,2.0,©'0at11 <br />