Laserfiche WebLink
„SSpp Marion County <br /> ?_ Certificate of Satisfactory Completion 5155 Silverton Rd NE <br /> Salem,OR 97305 <br /> Marion <br /> co Repair (Major) - Residential - New 503-588-5147 <br /> Building@co.marion.or.us <br /> j R E.G'o N 555-22-006651-PRMT Website:co.marion.or.us <br /> ,- <br /> atedo,‘ cafe s(3$F12/20 �M ,a;s �;€�° t+ = $ • �� IF <br /> i don IA' kits SF[l • �� a : sn <br /> g <br /> Qro�- �. "€ �'x`q _ s<. �ss . � ”' p.,a .^w `� : ��.a` •+¢' w+x_'rn':: •"a.....aa �s... '. <br /> Applicant: E and Z Excavating LLC Primary Contractor: E and Z Excavating LLC <br /> Address: PO Box 453 Installer License:39104 <br /> Molalla OR 97038 Address: PO Box 453 <br /> Phone: (503)829-4070 Molalla OR 97038 <br /> Phone: (503)829-4070 <br /> Email: erineandz@gmail.com <br /> Email: erineandz@gmail.com <br /> Owner: PEREZ, MELISSA Property Address: 871 Iva Ln NE, Salem,OR 97317 <br /> Address: 871 IVA LN NE <br /> SALEM OR 97317 <br /> Parcel:072W20D 01700-Primary <br /> Lot Size: 0.91 Water Supply: Well <br /> Zoning: N/A City/County/UGB: N/A <br /> Land Use Approval: N/A <br /> Category of Construction: N/A <br /> Use of Structure: N/A single family dwelling <br /> Number of Bedrooms: 4 N/A <br /> System Specifications <br /> Type: Alternative Treatment Technology(ATTs) ATT Description: Norweco Sinulair with UV <br /> Max Peak Design Flow: 450 gpd. Proposed Flow: 225 gpd. <br /> Min Septic Tank Volume: 1000 gal. Min Dosing Tank Volume: N/A <br /> Special Tank Requirements: Waite single compartment gravity flow ANTIBUOYANCEY FOR TANK AND ATT UNIT REQUIRED <br /> Drain Field Specifications <br /> Drain Field Type: Gravelless System Distribution Type: Equal <br /> Drainfield Sizing: N/A Distribution Method: Gravelless Half Pipe <br /> Media Type: infiltrator quick4 Media Depth: N/A <br /> Trench Length: 144 linear ft. Rock Above Pipe: N/A <br /> Max Depth: 14 in. Undisturbed Soil BetweenTrenches: 10 ft. <br /> Min Depth: 12 in. Capping Fills-Min Depth of Fill Material: 4 in. <br /> Special Requirements <br /> Permanent Groundwater De the N/A <br /> Groundwater Type: p <br /> Pump to Drainfield Required: Yes Filter Fabric on Top of Drain Media: No <br /> Other Special Rquirements: All irrigation piping must be removed from this area and 10 ft surrounding cap, ONLY INSTALLED IN <br /> THE DRY MONTHS OF THE YEAR JUNE TO OCTOBER 1ST, NO EXCEPTIONS, NO INCREASE <br /> IN FLOW ALLOWED EVER,SOILS ARE ONLY BEING APPROVED FOR A REPAIR UNDER <br /> REASONABLE REPAIR RULE 0 and M contract required for the life of the system needs tank <br /> abandonment and pumping receipt prior to finalling system <br /> 8/12/24:12:18:48PM ONS_OnsiteCSCpr <br />