Laserfiche WebLink
Onsite Permit 555-24-004158-PRMT Page 2 of 3 <br /> Schedule or track inspections at www.buildingpermits.oregon.gov <br /> Call or text the word "schedule"to 1-888-299-2821 use IVR Number:555050077780 <br /> y Schedule using the Oregon ePermitting Inspection App,search"epermitting"in the app store <br /> ! a'•W.� *% C" - i4., � N,:,., ' .o g 3'�b §C" 5 J, <•:r '�' �b H L3 eY 'R�I�n'. <br /> 17a a issti ,6'124 i :� � r 7 r �€ -, p ration bate ! 4'12 <br /> '4. 4 �„£ •P. w � , ey -_;. '"z <br /> 'ftitork descrrptiian A:I =�R I;�AACE FAILING S ,ORt3EPR SFp ti ,„ <br /> Media type: Other-Indicate Product/Manufacturer Media depth: N/A <br /> Media type description: EZ-Flow <br /> Trench length: 375 linear ft. Rock above pipe: N/A <br /> Max depth: 14 in. Undisturbed soil between trenches: 8 ft. <br /> Min depth: 12 in. Capping fills-min depth of fill material: 16 in. <br /> Special Requirements <br /> Stake out required: Yes <br /> Groundwater type: Temporary Groundwater depth: 20 in. <br /> Pump to drainfield reqd: Yes Filter fabric on top of drain media: N/A <br /> Conditions of approval <br /> -Capping fill rules at OAR 340-071-0265.Construction must occur in dry soil conditions between June 1 and <br /> October 1 unless otherwise approved by the agent.The cap material must be pre-approved by the agent prior to <br /> placement.Minimum 10-ft between edge of fill and trench.Drainfield area must be scarified.Contact between <br /> native soil and fill must be mixed.Final cap to be seeded and or landscaped to prevent erosion. Protect from <br /> livestock and vehicular traffic. <br /> Serial distribution.The cap material must be evenly graded to a final depth of 16-inches over the drain media. <br /> •Dry soil installation only(June 1 —October 1 unless otherwise authorized by the agent). <br /> •The system must be installed by the property owner or a licensed sewage disposal business <br /> (installer). <br /> -Vehicular traffic and livestock must be restricted from the system area. <br /> •All roof drains must be directed away from the system <br /> -All tanks must be tested for watertightness and have a water-tight riser to the ground surface.Twenty-inch <br /> minimum diameter if less than 36-in deep.Thirty-inch minimum diameter if greater than 36-in deep. Maintain <br /> access to septic tank for pumping and service. <br /> -Meet all required setbacks <br /> -The system must be installed in the area approved during the site evaluation and in accordance with the <br /> construction plan approved by the agent, including any changes made by the agent. <br /> •All work is to conform to OAR 340, Division 71 and 73. Make no changes in system location or specifications <br /> without approval by the agent. <br /> •For product approval information and manufacturer installation requirements see DEQ website at: <br /> http://www.oregon.gov/deq/Residential/Pages/Onsite.aspx <br /> •The pump and alarm must be wired on separate circuits in the control panel. Pump wiring must comply with <br /> applicable building,electrical,or other codes.An electrical permit and inspection from the Department of <br /> Consumer and Business Services,Building Codes Division,or the municipality with jurisdiction, is required for <br /> pump wiring installation. <br /> •Install the pump and system components in accordance with the approved pump curve and specifications. <br /> •An anti-buoyancy device is required for the septic tank(s)and must be installed as per the <br /> manufacturer installation guidelines. <br /> •A minimum 18-gauge,green-jacketed tracer wire or green color-coded metallic tape must be placed on top of <br /> the effluent sewer or pressure transport pipe from tank to drainfield. <br /> -Header pipe from Distribution or Drop Box must be minimum 4-ft length,level,and bedded. <br /> •Each drainfield trench must be level within a tolerance of plus or minus 1-inch. <br /> -Maximum length of an individual trench is 150-feet. <br /> -Serial distribution,each trench bottom to be level and on contour. Use Drop box(es). <br /> 6/24/24:8:42:55AM ONS_OnsitePermit_pr <br />