Laserfiche WebLink
Onsite Permit 555-24-000303-PRMT Page 3 of 4 <br /> Schedule or track inspections at www.buildingpermits.oregon.gov <br /> Call or text the word "schedule"to 1-888-299-2821 use IVR Number:555050559534 <br /> Schedule using the Oregon ePermitting Inspection App, search"epermitting"in the app store <br /> L?ateissueit 3f7124/V P � AE � y �� � E�cpiration a 3f712 <br /> '�". ',1 ,�E r'k .t' RN k€0.�`d a 0'3' r.�s; }"' zs,''r ,4 ,,, 4iig fig r" ate:. <br /> Work descrt on�M M zT FOR FUTURE 4 8D 4& � <br /> ,�"«e.�?h��'r'^ s' c<s 6 7,* .. `��n`z, `,�':fC ' ..:,, ' �i33 ��&1'` wroAK7 ,a<.. . i,. �a�;e'h�,•F y,�+.e�. E +.#�.r' <br /> Conditions of approval <br /> •This permit is for the installation of an Alternative Treatment Technology(ATT)system and is to be installed by <br /> a person certified by the system manufacturer in accordance with OAR 340-071-0600 and 0650.See Alternative <br /> Treatment Technology rules at OAR 340-071-0345. <br /> •ATT treatment standard 2 required. <br /> •The ATT system must be designed to prevent untreated waste from passing into the absorption field if the <br /> treatment system malfunctions. <br /> •The septic tank must be approved for use with the ATT system to be installed. <br /> •In addition to the As-Built and Materials List,a Start-Up checklist from the ATT maintenance provider is <br /> required to Final this permit. <br /> •The owner of an ATT system must maintain a contract with a maintenance provider certified by the <br /> manufacturer to inspect,adjust and maintain the onsite system.The maintenance provider must submit an annual <br /> report and annual evaluation fee. <br /> •Capping fill rules at OAR 340-071-0265.Construction must occur in dry soil conditions between June 1 <br /> and October 1 unless otherwise approved by the agent.The cap material must be pre-approved by the <br /> agent prior to placement.Minimum 10-ft between edge of fill and trench.Drainfield area must be <br /> scarified.Contact between native soil and fill must be mixed.Final cap to be seeded and or <br /> landscaped to prevent erosion.Protect from livestock and vehicular traffic. <br /> •Equal distribution.The cap material must be evenly graded to a final depth of 10-inches over the drain media. <br /> •Vehicular traffic and livestock must be restricted from the system area. <br /> •All roof drains must be directed away from the system <br /> •All tanks must be tested for watertightness and have a water-tight riser to the ground surface.Twenty-inch <br /> minimum diameter if less than 36-in deep.Thirty-inch minimum diameter if greater than 36-in deep.Maintain <br /> access to septic tank for pumping and service. <br /> •Meet all required setbacks <br /> •The system must be installed in the area approved during the site evaluation and in accordance with the <br /> construction plan approved by the agent, including any changes made by the agent. <br /> •All work is to conform to OAR 340,Division 71 and 73.Make no changes in system location or specifications <br /> without approval by the agent. <br /> •For product approval information and manufacturer installation requirements see DEQ website at: <br /> http://www.oregon.gov/deq/Residential/Pages/Onsite.aspx <br /> •The pump and alarm must be wired on separate circuits in the control panel. Pump wiring must comply with <br /> • <br /> applicable building,electrical,or other codes. An electrical permit and inspection from the Department of <br /> Consumer and Business Services,Building Codes Division,or the municipality with jurisdiction,is <br /> required for pump wiring installation. <br /> •Install the pump and system components in accordance with the approved pump curve and specifications. <br /> •An anti-buoyancy device is required for the septic tank(s)and must be installed as per the <br /> manufacturer installation guidelines. <br /> •A minimum 18-gauge,green jacketed tracer wire or green color-coded metallic tape must be placed on top of <br /> the effluent sewer or pressure transport pipe from tank to drainfield. <br /> •Header pipe from Distribution or Drop Box must be minimum 4-ft length,level,and bedded. <br /> -Each drainfield trench must be level within a tolerance of plus or minus 1-inch. <br /> •Maximum length of an individual trench is 150-feet. <br /> •Equal distribution,all trench bottoms must be at the same elevation. Use Distribution box(es). <br /> 3/7/24:8:28:22AM ONS_OnsitePennit_pr <br />