Laserfiche WebLink
Onsite Permit 555-22-007821-PRMT-01 Page 2 of 3 <br /> Schedule or track inspections at www.buildingpermits.oregon.gov <br /> Call or text the word "schedule" to 1-888-299-2821 use IVR Number:555007450037 <br /> Schedule using the Oregon ePermitting Inspection App, search"epermitting"in the app store <br /> ..;,e...,n..._-c^•.,..,..a.....,:....,,.--.,,. _ ... ^roar;-aa.,,� � <br /> ..+%-^5 a'S"" +aswn J+.,�^ Cs a .a a5...r.(...�.n pr . <br /> a�-f ari[L f� +�� '� ��.0 n�.. `a b) s.Sr< s-w,�a ,F,L 4 gr"7,a. ,�u.�~` �s %. <br /> tf <br /> '+s w. BNxsz,ffi.��....,....� �• _ .._.......,..........,..&.x-.��ra...........�.�<.,�..,,..zm..�s.�s�a..�..,,.��s�m.... <br /> Total rock depth: 12 in. Rock below pipe: 6 in. <br /> Max depth: 30 in. Undisturbed soil between trenches: N/A <br /> Min depth: 18 in. Capping fills-min depth of fill material: N/A <br /> Special Requirements <br /> Pump to drainfield reqd: Yes Filter fabric on top of drain media: Yes <br /> Other special rqmt: inspection ports at ends of lines <br /> Conditions of approval <br /> •The owner of a pressurized distribution system must maintain a contract with a certified <br /> maintenance provider to inspect, adjust and maintain the onsite system.The maintenance <br /> provider must submit an annual report and annual evaluation fee. <br /> -Filter fabric required over drain media(rapidly permeable soils). <br /> •Pressurized distribution rules at OAR 340-071-0275. Install sweep elbows at ends of lateral <br /> piping with acceptable threaded plugs or caps. Minimum head of 5-ft at remotest orifice, less <br /> than 10%variation. <br /> •Dry soil installation only(June 1 —October 1 unless otherwise authorized by the agent). <br /> •The system must be installed by the property owner or a licensed sewage disposal <br /> business(installer). <br /> -Vehicular traffic and livestock must be restricted from the system area. <br /> •All roof drains must be directed away from the system <br /> -All tanks must be tested for watertightness and have a water-tight riser to the ground <br /> surface.Twenty-inch minimum diameter if less than 36-in deep.Thirty-inch minimum <br /> diameter if greater than 36-in deep. Maintain access to septic tank for pumping and service. <br /> 'Meet all required setbacks <br /> •The system must be installed in the area approved during the site evaluation and in <br /> accordance with the construction plan approved by the agent, including any changes made <br /> by the agent. <br /> -All work is to conform to OAR 340, Division 71 and 73.Make no changes in system location <br /> or specifications without approval by the agent. <br /> •For product approval information and manufacturer installation requirements see DEQ <br /> website at: http://www.oregon.gov/deq/Residential/Pages/Onsite.aspx <br /> •The pump and alarm must be wired on separate circuits in the control panel. Pump wiring <br /> must comply with applicable building, electrical,or other codes.An electrical permit and <br /> inspection from the Department of Consumer and Business Services, Building Codes <br /> Division, or the municipality with jurisdiction, is required for pump wiring installation. <br /> -Install the pump and system components in accordance with the approved pump curve and <br /> specifications. <br /> 10/8/23:8:49:19AM ONS OnsitePermit_pr <br />