Septic Permit 555-22-010453-PRMT-01 Page 2 of 3
<br /> ,�`��"-� �k � x x r ..�,� :�' n ��+q� �w.•`P ems`,.-: �'�., `'�3 ,.� �••F" d '�r s '
<br /> Date.Gart ec'ete lssueal 08/21l202
<br /> m "a ��k � ear��€:.,:*4� x•�r.,m,,.M� 6,p^+f�°''• �v ���,� �. e.�$e� � �> Ye � x � � �" �e
<br /> �i a Kit '* e "� '�'
<br /> Worl'I� ckr Lion i ��A "tt�tlff¢TAf� fNT()EX[t� t,�R 4�BOFtiul�S(�D�TO�REP� HDRM,Si�'k° ,k,Z �� � � -
<br /> :. ,. , C,ott1VP-or pt p 9,Y#I ., 4
<br /> •The system must be installed by the property owner or a licensed sewage disposal business(installer).
<br /> •Vehicular traffic and livestock must be restricted from the system area.
<br /> •All roof drains must be directed away from the system
<br /> •All tanks must be tested for watertightness and have a water-tight riser to the ground surface.Twenty-inch
<br /> minimum diameter if less than 36-in deep.Thirty-inch minimum diameter if greater than 36-in deep. Maintain access
<br /> to septic tank for pumping and service.
<br /> •Meet all required setbacks
<br /> •AII work is to conform to OAR 340, Division 71 and 73. Make no changes in system location or specifications
<br /> without approval by the agent.
<br /> •For product approval information and manufacturer installation requirements see DEQ website at:
<br /> http://www.oregon.gov/deq/Residential/Pages/Onsite.aspx
<br /> •The pump and alarm must be wired on separate circuits in the control panel. Pump wiring must comply with
<br /> applicable building, electrical, or other codes.An electrical permit and inspection from the Department of Consumer
<br /> and Business Services, Building Codes Division, or the municipality with jurisdiction, is required for pump wiring
<br /> installation.
<br /> Install the pump and system components in accordance with the approved pump curve and specifications.
<br /> Installation of this onsite wastewater treatment system has been determined to comply with the applicable requirements in
<br /> Oregon Administrative Rules Chapter 340, Divisions 071 and 073 and the Conditions of Approval above.
<br /> 1. In accordance with Oregon Revised Statute 454,665,this Certificate of Satisfactory Completion is issued as evidence of
<br /> satisfactory completion of an onsite wastewater treatment system at the location identified above.
<br /> 2. Issuance of this Certificate does not constitute a warranty or guarantee that this onsite wastewater treatment system will
<br /> function indefinitely without failure.Conditions imposed as permit requirements continue for the life of the system.
<br /> 3.The area of the initial and the identified replacement area must not be subjected to activity that is likely to adversely affect
<br /> the soil or the functioning of the system.Such activities may include, but are not limited to,vehicular traffic, livestock,
<br /> covering the area with asphalt or concrete,filling,cutting,or other soil modification activities.
<br /> 4.This onsite wastewater treatment system that be connected to the facility referenced herein within 5 years of the issuance
<br /> of this Certificate of Satisfactory Completion(CSC)or rules for authorization notices,alteration permits,or
<br /> construction-installation permits as outlined in OAR 340-071-0160,340-071-0205,or 340-071-0210 apply,including payment
<br /> of an additional fee.
<br /> 5.This system must operate in compliance with OAR Chapter 340, Division 071 and must not create a public health hazard
<br /> or pollute public waters.
<br /> 6.Unless otherwise required by the agent,the system installer must backfill(cover)this system within 10 days after the
<br /> issuance of this Certificate of Satisfactory Completion."Nf
<br /> ;tom . h. .. �G�rtrficte.af Satisfactory comptltxrs K
<br /> _ .«n. �3,; e,.n,,, u, t,v'ms a._ _ws�- ,n.,s_.,, a,.. n °<,.�a.,=4�:aee ;:.. .°. one°��,,. ,4,tt
<br /> System Inspection: Yes Operation of Law-7 Days Notice: No Pre-Cover Inspection Waived Per 340-071: No
<br /> Comments: N/A
<br /> � � � €ant�teted>f �etcas •
<br /> ,�.. et v;, �' '�`���«r✓�� a3� � ��r ...„r<„„ .� a,.,, �.r � . ,,,� ��<..-dre r,:. ky
<br /> Inspector Inspection Inspection Date Inspection Result
<br /> Danielle Brown 7310 Pump/Alarm System 08/22/2024 Approved
<br /> Danielle Brown 7999 Final Septic 08/22/2024 Approved
<br /> Danielle Brown 7170 Septic Tank Abandonment 08/20/2024 Approved
<br /> Kimberlee Aldrich 7270 Tank Water Tightness 06/10/2024 Approved
<br /> 8/23/24:2:19:07PM ONS_OnsiteCSC pr
<br />
|