Laserfiche WebLink
Septic Permit 555-21-007762-PRMT Page 2 of 3 <br /> Date Certificate tssrrecf 08129/2C124 � , , � � t <br /> t�Itorl�De�crrptioit �� �TR� MA.J�,e ,�� �. � � 6 � � ��+0 <br /> �+ ::--.?x sue.;, x,��g; %a '""z v./.C✓ 3 d .`b ^bfo = <br /> r- ds f4W- '� ` ,�' �"? ,'�"�','�'a .fix: r /� �`s3#»'"",,w ;, rNs .:y ,�,,.-. �rx$ ':� `` , w�, s v, x <br /> 3 r ; 2 a cort,,4 4. 'fs rovesAiyy ,,� �< <br /> •This major repair permit is to install a new septic system for a property that was damaged by the Beachie Creek Fire <br /> of 2020 <br /> •Pressurized distribution rules at OAR 340-071-0275.Install sweep elbows at ends of lateral piping with acceptable <br /> threaded plugs or caps.Minimum head of 5-ft at remotest orifice,less than 10%variation. <br /> •The owner of a pressurized distribution system must maintain a contract with a certified maintenance provider to <br /> inspect,adjust and maintain the onsite system.The maintenance provider must submit an annual report and annual <br /> evaluation fee. <br /> •The system must be installed by the property owner or a licensed sewage disposal business(installer). <br /> •An electrical permit and inspection from the Department of Consumer and Business Services,Building Codes <br /> Division,or the municipality with jurisdiction,is required for pump wiring installation. <br /> •Filter fabric required over drain media(rapidly permeable soils). <br /> •Vehicular traffic and livestock must be restricted from the system area. <br /> •All roof drains must be directed away from the system <br /> •All tanks must be tested for watertightness and have a water-tight riser to the ground surface.Twenty-inch minimum diameter if <br /> less than 36-in deep.Thirty-inch minimum diameter if greater than 36-in deep. Maintain access to septic tank for pumping and <br /> service. <br /> •Meet all required setbacks <br /> •The system must be installed in the area approved during the site evaluation and in accordance with the construction plan <br /> approved by the agent,including any changes made by the agent. <br /> •The pump and alarm must be wired on separate circuits in the control panel. Pump wiring must comply with applicable building, <br /> electrical,or other codes. <br /> •Install the pump and system components in accordance with the approved pump curve and specifications. <br /> •A minimum 18-gauge,green-jacketed tracer wire or green color-coded metallic tape must be placed on top of the effluent sewer <br /> or pressure transport pipe from tank to drainfield. <br /> •All work is to conform to OAR 340, Division 71 and 73. Make no changes in system location or specifications without approval <br /> by the agent. <br /> •For product approval information and manufacturer installation requirements see DEQ website at: <br /> http://www.oregon.gov/deq/Residential/Pages/Onsite.aspx <br /> Installation of this onsite wastewater treatment system has been determined to comply with the applicable requirements in <br /> Oregon Administrative Rules Chapter 340, Divisions 071 and 073 and the Conditions of Approval above. <br /> 1. In accordance with Oregon Revised Statute 454,665,this Certificate of Satisfactory Completion is issued as evidence of <br /> satisfactory completion of an onsite wastewater treatment system at the location identified above. <br /> 2. Issuance of this Certificate does not constitute a warranty or guarantee that this onsite wastewater treatment system will <br /> function indefinitely without failure.Conditions imposed as permit requirements continue for the life of the system. <br /> 3.The area of the initial and the identified replacement area must not be subjected to activity that is likely to adversely affect <br /> the soil or the functioning of the system.Such activities may include,but are not limited to,vehicular traffic, livestock, <br /> covering the area with asphalt or concrete,filling,cutting,or other soil modification activities. <br /> 4.This onsite wastewater treatment system that be connected to the facility referenced herein within 5 years of the issuance <br /> of this Certificate of Satisfactory Completion(CSC)or rules for authorization notices,alteration permits,or <br /> construction-installation permits as outlined in OAR 340-071-0160,340-071-0205,or 340-071-0210 apply,including payment <br /> of an additional fee. <br /> 5.This system must operate in compliance with OAR Chapter 340, Division 071 and must not create a public health hazard <br /> or pollute public waters. <br /> 6. Unless otherwise required by the agent,the system installer must backfill(cover)this system within 10 days after the <br /> issuance of this Certificate of Satisfactory Completion. <br /> .F,y.s l �ro 3gA,�t*x ' '. ,t .S•s f gr - a 4 �', <br /> m&3 o 6 Certtficaf of Satrsfacla�Compt3n <br /> .-., ,ma tor, n,e.A�—..� ..� ... _. .. .,. -»S9 .-.. .R$n�.. .n fr* ., h ..frw _... <br /> System Inspection: Yes Operation of Law-7 Days Notice: No Pre-Cover Inspection Waived Per 340-071: No <br /> Comments: The system was finaled on temporary power and a Certificate of Satisfactory Completion was issued on 08/29/2024. <br /> Final electrical connection to the septic system must be verified prior to C of 0 issuance. <br /> ,.� h h.,.> .:.. �� 2 g.«.,,� ,. <br /> 8/29/24:12:13:45PM ONS_OnsiteCSC jr <br />