Laserfiche WebLink
Onsite Permit 555-21-007762-PRMT Page 2 of 3 <br /> Schedule or track inspections at www.buildingpermits.oregon.gov <br /> Call or text the word "schedule" to 1-888-299-2821 use IVR Number:555037006755 <br /> Schedule using the Oregon ePermitting Inspection App, search"epermitting"in the app store <br /> Dater ued O,Q{2=�f2• ,h r � 'per y�l f a m a t p �` 4,� 1 .sir y A <br /> � � � � �� ,��� � : ��3� a ��� � v � � .� ,�� „�«� � -��cp,>ca�b,o�n�daY��(ft2"f�{22'. <br /> 4 633 •E cEc^.rFL J "`XP <br /> '"� rr�- +: >a, ,.�,a�3 n, � z <br /> ■for d,eR7PtIora<„ l MAc REl�y _''..� ." a. �^ r� ' <br /> i,r-;: -Y� �yk A .M3 �s �. 3 " ¢" �.�,'am" -�- A r s �k -� '",:: <br /> .,�._:.�.,...�...._ .;.._ �_._.- ..._.__ <br /> Special Requirements <br /> Stake out required: No <br /> Pump to drainfield reqd: Yes Filter fabric on top of drain media: Yes <br /> Other special rqmt: install per approved plans <br /> Conditions of approval <br /> •This major repair permit is to install a new septic system for a property that was damaged by the <br /> Beachie Creek Fire of 2020 <br /> •Pressurized distribution rules at OAR 340-071-0275.Install sweep elbows at ends of lateral piping with <br /> acceptable threaded plugs or caps.Minimum head of 5-ft at remotest orifice,less than 10%variation. <br /> •The owner of a pressurized distribution system must maintain a contract with a certified <br /> maintenance provider to inspect,adjust and maintain the onsite system.The maintenance provider <br /> must submit an annual report and annual evaluation fee. <br /> -The system must be installed by the property owner or a licensed sewage disposal business <br /> (installer). <br /> •An electrical permit and inspection from the Department of Consumer and Business Services, <br /> Building Codes Division,or the municipality with jurisdiction,is required for pump wiring installation. <br /> •Filter fabric required over drain media(rapidly permeable soils). <br /> •Vehicular traffic and livestock must be restricted from the system area. <br /> •All roof drains must be directed away from the system <br /> •All tanks must be tested for watertightness and have a water-tight riser to the ground surface.Twenty-inch <br /> minimum diameter if less than 36-in deep.Thirty-inch minimum diameter if greater than 36-in deep. Maintain <br /> access to septic tank for pumping and service. <br /> •Meet all required setbacks <br /> •The system must be installed in the area approved during the site evaluation and in accordance with the <br /> construction plan approved by the agent, including any changes made by the agent. <br /> •The pump and alarm must be wired on separate circuits in the control panel. Pump wiring must comply with <br /> applicable building, electrical, or other codes. <br /> •Install the pump and system components in accordance with the approved pump curve and specifications. <br /> •A minimum 18-gauge,green jacketed tracer wire or green color-coded metallic tape must be placed on top of <br /> the effluent sewer or pressure transport pipe from tank to drainfield. <br /> •All work is to conform to OAR 340, Division 71 and 73.Make no changes in system location or specifications <br /> without approval by the agent. <br /> •For product approval information and manufacturer installation requirements see DEQ website at <br /> http://www.oregon.govkleq/Residential/Pages/Onsite.aspx <br /> 10/21/21:3:18:24PM ONS_OnsitePermitpr <br />