My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
12380178
Images9
>
Public Works - Permits
>
Building
>
FOR PUBLIC VIEW ON INTERNET
>
COMPLETED FILES - INACTIVE
>
24-XXXXX
>
12380178
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/26/2024 12:46:22 PM
Creation date
9/19/2024 4:49:35 PM
Metadata
Fields
Template:
Permits
Permit Address
67 ANKENY HILL RD SE
Permit City
Jefferson
Permit Number
555-24-007093-AUTH
Parcel Number
093W09 00800
Permit Type
Authorization
Permit Doc Type
Permit Document
Status
Ready to Film
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
15
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
Oregon Department of Environmental Quality <br /> • Dosing tank capacity 500 (gallons) <br /> • Tank volume determined by: Check all that apply, add comments below as needed <br /> ❑✓ Permit Records ❑ Measured n Stamped on Tank❑ Other <br /> • Dosing tank material Concrete <br /> • Dosing tank appears to be watertight and in good condition �/Yes ❑No <br /> • Dosing tank lid is intact ©Yes ❑No <br /> • Electrical components are sealed and watertight n✓Yes ❑No <br /> • Pump/siphon is functional [—Wes ❑No <br /> • Type of Pump Demand dose ❑Time dose <br /> • Pump control mechanism is functional(floats,pressure transducer) ✓❑Yes nNo <br /> • There is a high water alarm n✓Yes [-No <br /> • The high water alarm(audible and visual) is working nYes ❑No ❑Not Applicable <br /> • Type of screen Bio screen <br /> • Screen is clean and free of debris❑✓Yes ❑No- Screen cleaned for this evaluation Yes ❑No <br /> • Scum/sludge present in Dosing tank ®Yes nNo <br /> • Scum layer 1 (inches) Sludge layer 3 (inches) <br /> • Additional Comments: <br /> 5. Soil absorption system <br /> The soil absorption system is a set of trenches that receives effluent from the septic tank and <br /> filters the effluent before it enters the groundwater. <br /> • The septic system has a soil absorption system❑✓Yes nNo ❑Unknown <br /> • Was the soil absorption system part of the evaluation?[Yes nNo ❑See note below <br /> If the soil absorption system was not evaluated,please explain below(for example unable to <br /> locate,client did not authorize this part of the evaluation): <br /> • Absorption distribution nEqual nSerial nPressure ❑Equal via pressure <br /> • Absorption lines construction material: <br /> ❑ Gravel and pipe ❑ Chamber ❑Tile ❑ Polystyrene foam and pipe ❑Other <br /> • Absorption distribution unit(s): ndropbox nhydrosplitter['equal distribution box <br /> ❑ Intact n Damaged ❑N/A <br /> • Absorption distribution unit(s)are free of debris or solids ❑Yes ❑No ❑N/A <br /> Page 4 of 8 <br />
The URL can be used to link to this page
Your browser does not support the video tag.