Aidan Bammes <br /> From: Aidan Bammes <br /> Sent: Tuesday,January 30, 2024 12:29 PM <br /> To: Drew <br /> Cc: Marc Burleson <br /> Subject: RE: 135 Santiam Ave <br /> For this project,the following alternatives are available. <br /> 1. Seepage Trenches, <br /> a. Installation Depth 40-42", <br /> b. 24 inches of rock below pipe, <br /> c. 43ft/150 gals, <br /> d. 3 bdrm sfd sized at 375 gpd max <br /> e. 107.5 linear feet of seepage trench <br /> 2. Standard <br /> a. Installation depth 24-36", (unless equal can be achieved then 18-36") <br /> b. 6 inches rock under pipe <br /> c. 75 ft/150 gals <br /> d. Same sizing <br /> e. 225 ft of drainfield <br /> 3. ATT would downsize standard drainfield to 112.5 <br /> 4m <br /> Aidan Bammes, REHS I Onsite Wastewater Specialist II <br /> Pronouns:They/Them/Theirs;He/Him/His <br /> Mn J Building Inspection,Marion County Public Works <br /> COunt <br /> gabammes@co.rnarion.or.us <br /> co.marion.or.us <br /> OREGON le(503)365-3165 (office) <br /> From: Drew<Drew@owenconstructioninc.com> <br /> Sent:Tuesday,January 30, 2024 12:09 PM <br /> To:Aidan Bammes<ABammes@co.marion.or.us> <br /> Cc: Marc Burleson<MARC@westpeakcommercial.com> <br /> Subject: 135 Santiam Ave <br /> Ab WARNING:This email originated outside of Marion County. <br /> DO NOT CLICK links or attachments unless you trust the sender and know the content is safe. <br /> Aidan, <br /> Do you have the sizing factor for this to not do a pressure distribution system? <br /> Thank you <br /> 1 <br />