Laserfiche WebLink
Onsite Permit 555-24-005279-PRMT Page 2 of 3 <br /> Schedule or track inspections at www.buildingpermits.oregon.gov <br /> Call or text the word "schedule"to 1-888-299-2821 use IVR Number:555089120800 <br /> Schedule using the Oregon ePermitting Inspection App,search"epermitting"in the app store tG <br /> Date sued 7115/ 4 F sf ' g e " ax e' • X `'�8 f p <br /> - �xf —r i ra a o 5125 <br /> � �$�'_^`* <br /> NUo sCrt•+an «: sa 4 ' ih y 3 <br /> A <br /> � °;", ..«, ti�U'� ;ti"m"4' .+�„�•s'S° a � ;X,,�J �.,�, $ 7.',.�. >. ��,�"iF,$4.�c� �,; a t i', � `..� � ..�u�.� ��&a,X ram+;. � �� �,�'' •��",{A <br /> :t <br /> 4.4 <br /> Max depth: 22 in. Undisturbed soil between trenches: 8 ft. <br /> Min depth: 18 in. Capping fills-min depth of fill material: N/A <br /> Special Requirements <br /> Stake out required: Yes <br /> Groundwater type: Temporary Groundwater depth: 26 in. <br /> Other special rqmt: An approved final electrical inspection is required to obtain the Certificate of Satisfactory Completion <br /> Conditions of approval <br /> •Dry soil installation only(June 1 —October 1 unless otherwise authorized by the agent). <br /> •The system must be installed by the property owner or a licensed sewage disposal business(installer). <br /> •Vehicular traffic and livestock must be restricted from the system area. <br /> •All roof drains must be directed away from the system <br /> •AII tanks must be tested for watertightness and have a water-tight riser to the ground surface.Twenty-inch <br /> minimum diameter if less than 36-in deep.Thirty-inch minimum diameter if greater than 36-in deep.Maintain <br /> access to septic tank for pumping and service. <br /> .Meet all required setbacks <br /> •The system must be installed in the area approved during the site evaluation and in accordance with the <br /> construction plan approved by the agent, including any changes made by the agent. <br /> •All work is to conform to OAR 340,Division 71 and 73.Make no changes in system location or specifications <br /> without approval by the agent. <br /> •For product approval information and manufacturer installation requirements see DEQ website at: <br /> http://www.oregon.govideq/ResidentiaUPages/Onsite.aspx <br /> •The pump and alarm must be wired on separate circuits in the control panel. Pump wiring must comply with <br /> applicable building,electrical,or other codes.An electrical permit and inspection from the Department of <br /> Consumer and Business Services,Building Codes Division,or the municipality with jurisdiction,is required for <br /> pump wiring installation. <br /> Install the pump and system components in accordance with the approved pump curve and specifications. <br /> •A minimum 18-gauge,green-jacketed tracer wire or green color-coded metallic tape must be placed on top of <br /> the effluent sewer or pressure transport pipe from tank to drainfield. <br /> •Header pipe from Distribution or Drop Box must be minimum 4-ft length,level,and bedded. <br /> .Each drainfield trench must be level within a tolerance of plus or minus 1-inch. <br /> -Maximum length of an individual trench is 150-feet. <br /> -Equal distribution,all trench bottoms must be at the same elevation. Use Distribution box(es). <br /> 7/15/24:2:31:30PM ONS_OnsitePermitjr <br />