Laserfiche WebLink
Page 1 of 1 <br /> Robert Goodwin - 1569 Silver Falls Dr NE 555-22-003071 <br /> From: Robert Goodwin <br /> To: KEELYPICARD@GMAIL.COM <br /> Date: 4/20/2022 3:07 PM <br /> Subject: 1569 Silver Falls Dr NE 555-22-003071 <br /> Hi Ronald and Kelly, <br /> I have completed my initial review of your septic application at 1569 Silver Falls Dr NE Silverton. Before a <br /> permit can be issued the following items need to be addressed: <br /> 1.The proposed well appears to be less than 50' from the effluent sewer as required in OAR 340-71-0220(1) <br /> (j). Please revise either the well location or the effluent sewer to meet this setback. <br /> 2. Please indicate the spacing of drainfield trenches, a minimum of 8' of undisturbed earth is required by <br /> OAR 340-71-0220(7)(E) <br /> 3. Please show on the site plan the drop box and header pipes, meeting requirements of OAR 340-71-0220 <br /> (5) &(9). <br /> 4.The specific EZ Flow product specs submitted are not a DEQ approved product, DEQ approved products <br /> can be found at this link: https://www.oregon.gov/deq/Residential/Pages/Onsite-Products.aspx <br /> 5.The polylok d-box specs indicate the box can be configured for either a distribution box or a drop box. <br /> Please indicate how the box will be configured to meet requirements of OAR 340-73-0040(3). <br /> Please feel free to contact me with any questions. <br /> Thanks, <br /> Robert Goodwin, REHS <br /> Onsite Wastewater Specialist <br /> Marion County Public Works <br /> P) 503-566-3990 <br /> E) Rgoodwin@co.marion.or.us <br /> file:///C:/Users/Rgoodwin/AppData/Local/Temp/XPGrpWise/626021 B 1 GWM4M-MCP W... 4/20/2022 <br />