Laserfiche WebLink
Onsite Permit 555-22-003071-PRMT Page 2 of 3 <br /> Schedule or track inspections at www.buildingpermits.oregon.gov <br /> Call or text the word "schedule" to 1-888-299-2821 use IVR Number:555017727394 <br /> Schedule using the Oregon ePermitting Inspection App, search"epermitting"in the app store <br /> Date issued -519I22 s Expiration dafe`5/9123 <br /> Work description NE1/1t INSTALL 4 RD M RES , ' <br /> a _ e ram t i � v c a ' . <br /> '�'. �, '��- ,- N R f n �:....�3� C -- � <br /> Trench length: 375 linear ft. Rock above pipe: N/A <br /> Max depth: 30 in. Undisturbed soil between trenches: 8 ft. <br /> Min depth: 24 in. Capping fills-min depth of fill material: N/A <br /> Special Requirements <br /> Stake out required: No <br /> Conditions of approval <br /> •Dry soil installation only(June 1 —October 1 unless otherwise authorized by the agent). <br /> •The system must be installed by the property owner or a licensed sewage disposal <br /> business (installer). <br /> •Vehicular traffic and livestock must be restricted from the system area. <br /> •All tanks must be tested for watertightness and have a water-tight riser to the ground <br /> surface.Twenty-inch minimum diameter if less than 36-in deep.Thirty-inch minimum <br /> diameter,if greater than 36-in deep. Maintain access to septic tank for pumping and service. <br /> • •Meet all required setbacks <br /> •The system must be installed in the area approved during the site evaluation and in <br /> accordance with the construction plan approved by the agent, including any changes made <br /> by the agent. <br /> •AII work is to conform to OAR 340, Division 71 and 73. Make no changes in system location <br /> or specifications without approval by the agent. <br /> •Effluent sewer.The effluent sewer must extend at least 5 feet beyond the septic tank <br /> before connecting to the distribution unit. It must be installed with a minimum fall of 4 inches <br /> per 100 feet and at least 2 inches of fall from one end of the pipe to the other. In addition, <br /> there must be a minimum difference of 8 inches between the invert of the septic tank outlet <br /> and either the invert of the header to the distribution pipe of the highest lateral in a serial <br /> distribution field or the invert of the header pipe to the distribution pipes of an equal <br /> distribution absorption field. <br /> •A minimum 18-gauge,green jacketed tracer wire or green color-coded metallic tape must <br /> be placed on top of the effluent sewer or pressure transport pipe from tank to drainfield. <br /> -Header pipe from Distribution or Drop Box must be minimum 4-ft length, level, and <br /> bedded. <br /> •Each drainfield trench must be level within a tolerance of plus or minus 1-inch. <br /> -Maximum length of an individual trench is 150-feet. <br /> -Serial distribution, each trench bottom to be level and on contour. Use Drop box(es). <br /> 5/9/22:8:30:27AM ONS_OnsitePermit pr <br />