Laserfiche WebLink
Septic Permit 555-22-002725-PRMT Page 2 of 3 <br /> Date Ce frcafe tss$ . 0�27)2�1? � :� ', <br /> -� �.a.,w :w as 4 x �, r k , ' �.`ro 8 t <br /> orfcaes ption Pf RE® BDRM a aREPLr3'BI€ORM <br /> • s .+x4?P., ,r :r, .,,<+3 ai 4,P.a a;,� �., . .:a", , kt t"s ` <br /> .This repair permit is for replacement of the existing septic system following the Beachie Creek Fire of 2020 which burned this <br /> property.This is a reasonable repair per OAR 340-71-0215(2)and HB 2289.A 25'setback to the escarpment is required. <br /> Properly decommission the old septic tank and submit appropriate documentation. <br /> •The owner of an ATT system must maintain a contract with a maintenance provider certified by the manufacturer to inspect, <br /> adjust and maintain the onsite system.The maintenance provider must submit an annual report and annual evaluation fee. <br /> -The ATT system must be designed to prevent untreated waste from passing into the absorption field if the treatment system <br /> malfunctions. <br /> •In addition to the As-Built and Materials List,a Start-Up checklist from the ATT maintenance provider is required to Final this <br /> permit. <br /> Pressurized distribution rules at OAR 340-071-0275. Install sweep elbows at ends of lateral piping with acceptable threaded <br /> plugs or caps.Minimum head of 5-ft at remotest orifice, less than 10%variation. <br /> •All roof drains must be directed away from the system <br /> •All tanks must be tested for watertightness and have a water-tight riser to the ground surface.Twenty-inch minimum diameter if <br /> less than 36-in deep.Thirty-inch minimum diameter if greater than 36-in deep. Maintain access to septic tank for pumping and <br /> service. <br /> •The pump and alarm must be wired on separate circuits in the control panel. Pump wiring must comply with applicable building, <br /> electrical,or other codes.An electrical permit and inspection from the Department of Consumer and Business Services, Building <br /> Codes Division,or the municipality with jurisdiction,is required for pump wiring installation. <br /> •A minimum 18-gauge,green-jacketed tracer wire or green color-coded metallic tape must be placed on top of the effluent sewer <br /> or pressure transport pipe from tank to drainfield. <br /> Installation of this onsite wastewater treatment system has been determined to comply with the applicable requirements in <br /> Oregon Administrative Rules Chapter 340, Divisions 071 and 073 and the Conditions of Approval above. <br /> 1. In accordance with Oregon Revised Statute 454,665,this Certificate of Satisfactory Completion is issued as evidence of <br /> satisfactory completion of an onsite wastewater treatment system at the location identified above. <br /> 2. Issuance of this Certificate does not constitute a warranty or guarantee that this onsite wastewater treatment system will <br /> function indefinitely without failure.Conditions imposed as permit requirements continue for the life of the system. <br /> 3.The area of the initial and the identified replacement area must not be subjected to activity that is likely to adversely affect <br /> the soil or the functioning of the system.Such activities may include, but are not limited to,vehicular traffic, livestock, <br /> covering the area with asphalt or concrete,filling,cutting,or other soil modification activities. <br /> 4.This onsite wastewater treatment system that be connected to the facility referenced herein within 5 years of the issuance <br /> of this Certificate of Satisfactory Completion(CSC)or rules for authorization notices,alteration permits,or <br /> construction-installation permits as outlined in OAR 340-071-0160,340-071-0205,or 340-071-0210 apply, including payment <br /> of an additional fee. <br /> 5.This system must operate in compliance with OAR Chapter 340, Division 071 and must not create a public health hazard <br /> or pollute public waters. <br /> 6. Unless otherwise required by the agent,the system installer must backfill(cover)this system within 10 days after the <br /> issuance of this Certificate of Satisfactory Completion. <br /> System Inspection: Yes Operation of Law-7 Days Notice: No Pre-Cover Inspection Waived Per 340-071: No <br /> Comments: A Certificate of Satisfactory Completion was issued on 09/09/2024 and the system is authorized to connect to a <br /> 3BDRM Single Family Dwelling <br /> Cccnt?letecelnsp et.OPS <br /> Inspector Inspection Inspection Date Inspection Result <br /> Danielle Brown 7999 Final Septic 09/09/2024 Approved <br /> Danielle Brown 7020 Pre-cover 05/29/2024 Partial <br /> 9/9/24:2:21:42PM ONS_OnsiteCSCpr <br />