Septic Permit 555-24-002110-PRMT Page 2 of 2 <br /> :♦`. '-w� a'{ ' ,a,`/Tr r�(� /f� kt:, <br /> t ttettaifl� {f y14- ��i"T°a' b X a a' , <br /> 1�fa t rl Pm' �� l F , MA.i* e t3� � <br /> •This permit is for the installation of an Alternative Treatment Technology(ATT)system and is to be installed by a person certified <br /> by the system manufacturer in accordance with OAR 340-071-0600 and 0650.See Alternative Treatment Technology rules at OAR <br /> 340-071-0345. <br /> •ATT treatment standard 1 required. <br /> •The ATT system must be designed to prevent untreated waste from passing into the absorption field if the treatment system <br /> malfunctions. <br /> •The septic tank must be approved for use with the ATT system to be installed. <br /> 4n addition to the As-Built and Materials List,a Start-Up checklist from the ATT maintenance provider is required to <br /> Final this permit. <br /> •The owner of an ATT system must maintain a contract with a maintenance provider certified by the manufacturer to inspect, <br /> adjust and maintain the onsite system.The maintenance provider must submit an annual report and annual evaluation fee. <br /> •Pressurized distribution rules at OAR 340-071-0275. Install sweep elbows at ends of lateral piping with acceptable threaded <br /> plugs or caps.Minimum head of 5-ft at remotest orifice, less than 10%variation. <br /> •Filter fabric required over drain media(rapidly permeable soils). <br /> •The owner of a pressurized distribution system must maintain a contract with a certified maintenance provider to inspect,adjust <br /> and maintain the onsite system.The maintenance provider must submit an annual report and annual evaluation fee. <br /> Installation of this onsite wastewater treatment system has been determined to comply with the applicable requirements in <br /> Oregon Administrative Rules Chapter 340, Divisions 071 and 073 and the Conditions of Approval above. <br /> 1.In accordance with Oregon Revised Statute 454,665,this Certificate of Satisfactory Completion is issued as evidence of <br /> satisfactory completion of an onsite wastewater treatment system at the location identified above. <br /> 2.Issuance of this Certificate does not constitute a warranty or guarantee that this onsite wastewater treatment system will <br /> function indefinitely without failure.Conditions imposed as permit requirements continue for the life of the system. <br /> 3.The area of the initial and the identified replacement area must not be subjected to activity that is likely to adversely affect <br /> the soil or the functioning of the system.Such activities may include, but are not limited to,vehicular traffic, livestock, <br /> covering the area with asphalt or concrete,filling,cutting,or other soil modification activities. <br /> 4.This onsite wastewater treatment system that be connected to the facility referenced herein within 5 years of the issuance <br /> of this Certificate of Satisfactory Completion(CSC)or rules for authorization notices,alteration permits,or <br /> construction-installation permits as outlined in OAR 340-071-0160,340-071-0205,or 340-071-0210 apply,including payment <br /> of an additional fee. <br /> 5.This system must operate in compliance with OAR Chapter 340, Division 071 and must not create a public health hazard <br /> or pollute public waters. <br /> 6.Unless otherwise required by the agent,the system installer must backfill(cover)this system within 10 days after the <br /> issuance of this Certificate of Satisfactory Completion. <br /> Tb2q Y - /rdU Q£ per` (�aYt�i�y� wRit. <br /> 1 , mrtific sQ� a Il�t �°�/`�:Q"ArR"I t9.n <br /> System Inspection: Yes Operation of Law-7 Days Notice: No Pre-Cover Inspection Waived Per 340-071: No <br /> Comments: Must have an electrical inspection from house to control panel. <br /> Inspector Inspection Inspection Date Inspection Result <br /> Matt Knudsen 7030 Squirt Test 09/18/2024 Approved <br /> Matt Knudsen 7020 Pre-cover 09/18/2024 Approved <br /> Issued By: Matt Knudsen, Onsite Wastewater Specialist Effective Date: 09/27/2024 <br /> 'Acuff Kew <br /> CALL BEFORE YOU DIG...ITS THE LAW <br /> ATTENTION:Oregon law requires you to follow rules adopted by the Oregon Utility Notification Center. Those rules are set forth by Oregon Administration Rules.You may obtain <br /> copies of the rules by calling the center.(Note:The telephone number for the Oregon Utility Notification Center is 1.800-332-2344.) <br /> 9/27/24:8:13:08AM ONS_OnsiteCSC_pr <br />