Laserfiche WebLink
CONSTRUCTION REQUIREMENTS <br />(Continued): <br /> <br />26. Vent kitchen fan to outside via <br />metal ducts. <br /> <br />27. In bathrooms, water closet <br />compartments, laundry rooms and <br />similar rooms, a mechanical <br />ventilation system connected <br />directly to the outside, capable of <br />five air changes per hour shall be <br />provided where there are no openable <br />windows. OUBC 1205-a <br /> <br />28. Provide ali habitable rooms <br />with outside windows with net areas <br />of not less than 1/10 of floor areas <br />not 10 sq. ft. Every sleeping room <br />shall have an exterior door or not <br />less than 5.7 iq, ft. of openable <br />window, The min. net clear opening <br />height shall be 24 inches. The min. <br />net clear opening width shall be 20 <br />inches. The finished sill height <br />shall be not more then 44 inches. <br /> <br /> OUBC 1204 and 1205 (a) <br /> <br /> 29. Provide at least one <br /> Swinging (exit) door OUBC 3304 <br /> <br /> 30. Stairs: OUBC 3305 <br /> a. Max. 8" rise. Min. 9" run. <br /> b. Headroom over stairs 6 ' 6" <br /> min. <br /> c, Handrail designed for 20 <br /> lbs. lateral load. Table <br /> 23-c <br /> d. Stairways having less than <br /> 4 risers need not have <br /> handrails. 3306 (j) <br /> <br /> 31, Heating facilities capable of <br /> maintaining a temperature of 68 <br /> degrees F. ag a point 3' above the <br /> floor are required in all habitable <br /> roms. OUBC 1211 <br /> <br /> 32. Warm air furnace shall not be <br /> installed in a bedroom or bathroom, <br /> 0UMC 704 <br />3~_J~. Where bottom of glass light is <br />w~thin !8" of flooz~ and all glass <br />doors and wall panels of bathtub and <br />shower enclosures, must be of <br />laminated, tempered or wire glass. <br />OUBC 5406 (d) <br /> <br /> 34. Approved numbers or addresses <br /> shall be provided for all new <br /> buildings in such a position as to <br /> be plainly visible and legible from <br /> the street or road fronting the <br /> property. <br /> <br />35. Every dwelling shall be <br />provided with an approved product of <br />combustion detector other than heat <br />mounted on the ceiling or wall at a <br />point centrally located in the <br />corridor or area giving access to <br />sleeping rooms. Where sleeping <br />rooms are on an upper level, the <br />detector shall be placed at the <br />center of the ceiling directly above <br />the stairs, Care shall be exercised <br />when locating cold air return to <br />furnace so that air flow to detector <br />from non-sleeping areas is not <br />impeded. A smoke detector shall be <br />installed in the basement of <br /> <br /> 36" <br />(e) <br /> <br /> dwelling units having a stairway which <br />,. opens from the basement into the <br /> dwelling. Such detector shall be <br /> connected to a sounding device to provide <br /> an alarm which will be audible in the <br /> sleeping area. OUBC 1210 (a) <br /> <br /> 36. Loose-fill insulation. <br /> poured and spray-on type may be <br /> attic spaces where roof slope is <br /> <br /> Blown <br />used in <br />4 in ],2 <br /> <br /> or grater and there is at least 44" of <br /> headroom at the ridge. 5303 (a) 2.A <br /> <br /> 37. Thermal insulation shall not be <br /> installed within 3" of any metal chimney <br /> or gas vent. <br /> <br /> 38. Insulation requirements. <br /> Buildings with high-efficiency heating <br /> equipment such as: <br /> 1. He at pumps that shows a <br /> coefficient of performance as <br /> required in Table No. 53~D. <br /> 2. Gas and oil fired that shows a <br /> minimum combustion efficiency <br /> of 80 percent Annual Fuel Use <br /> Efficiency (AFUE) rating. <br /> May have building elements insulated as <br /> Fellows: <br /> Ceiling R-3 0 (roof/ceiling <br /> assemblies in which has a slope of 3 <br /> in 12 or greater, may be R-19). <br /> Walls R-19 <br /> Floors <br /> Other Heating systems: <br /> Ceilings R-38 (roof/ceiling <br /> assemblies in which as a slope <br /> of 3 in 12 or greater may be <br /> R-19) <br /> Walls <br /> Floors R-19 <br /> OUBC 5303 (c)l <br /> <br />O, Slab 24" length of R-4,5 <br /> min. <br /> znsulation placed between slab and <br /> foundation wall, length to include <br /> horizontal and vertical distance, 5303 <br /> (c) 4 <br />d Weatherstrip between heated <br /> doors <br />unheated areas. <br /> <br /> 41. Heat ducts installed under floor or <br /> in attic shall be provided min. R-4.5 <br /> <br /> INSULATION. <br /> <br /> 42. R-il perimeter insulation accepted <br /> when crawl space is a plenum. <br /> ............. <br /> t baffles are required at cave <br /> t deflect ventilation air over <br /> blown insulation. (OUBC Section) 5303 (a) <br /> 2A <br /> <br /> 44. Fireplace and chimney construction <br /> shall conform to chapter 37 OUBC <br />~, When alterations, repairs, or <br />~a~dditions having a valuation of $1,000.00 <br />occur, or sleeping rooms are added in <br />existing Group R, Division 3 occupancies, <br />the entire building shall be provided <br />with smoke detectors as specified in UBC <br />1210 (a) <br /> <br /> 46. Sky lights set at an angle less than <br /> 45 degree from horizontal shall be set at <br /> least 4" above the plane of roof on a <br /> curb contacted as required for the frame. <br /> <br /> <br />