Laserfiche WebLink
BUILDING INSPECTION <br />(503) 588,5147 <br /> <br />PLANNING & <br />F,N FORCI]M J]NT <br />(503) 588-503B <br /> <br />BOARD OF <br />COMMISSiONI~RS <br />Randal[ Fraflke <br /> <br />Garry Kanz <br /> <br />ADMINISTBATIVI~ <br />OFFIC£R <br /> <br />Marion County <br /> <br /> OREGON <br />COMMUNITY DEVELOPMENT <br /> DEPARTMENT <br /> <br /> October 7, 1988 <br /> <br />Mrs. Annette B. Kasel <br />21823 Airport Rd. NE <br />Aurora~ Oregon <br /> <br />Dear Mrs Kasel: <br /> <br /> An inspection of ~your proposed subdivision, known <br />as Kasel Court and located directly north of 21883 <br />Airport Road NE, Aurora, was conducted on September 26, <br />1988. The lots of the proposed subdivision do not meet <br />the requirements of the Department of Environmental <br />Quality On-Site Sewage Disposal Rules and cannot be <br />approved as submitted. <br /> <br /> The soils in all of the test holes consisted of a <br />surface layer, ranging from 36 inches to 48 inches, of <br />silt loam. This was underlain with a layer of salt loam <br />grading to a sandy loam to the bottom of the test holes <br />at a depth of 72 inches. No evidence of a temporary <br />water table or conditions associated with saturation <br />was observed in the test holes. With the exception of a <br />small area at the front of the property that has been <br />filled, the soils on the property are acceptable for <br />On-Site Sewage Disposal. <br /> <br /> The lots range in size from 12,776.62 sq. feet to <br />14,710.90 sq. feet. A site evaluation report was issued <br />in January of 1988 on Lot 1, which is 14,710.90 sq. <br />feet and the largest lot in the subdivision, and it was <br />determined at that time that there was just enough room <br />to allow for the installation of the initial septic <br />system and provide for the replacement area using a <br />sand filter alternative system for the replacement. <br />Based on that information, it does not seem feasible <br />that the remaining, smaller lots have sufficient area <br />for the required septic system and replacement area. If <br />it can be shown that there is sufficient area on each <br />lot, as required by the D.E.Q. rules, we could recon- <br />sider our decision. If you wish to consider this, have <br />a D.E.Q. licensed septic installer lay out the septic <br />system and replacement area on each lot and submit a <br />plot plan showing the placement of the drainfields. <br /> <br />Senator Building · 220 High Street NE Salem, Oregon 97301-3670 <br /> <br /> <br />