m'etal ducts, an alarm which will be audible in the <br /> <br /> 27. In bathrooms, water closet <br /> compartments, laundry rooms and <br /> similar rooms, a mechanical <br /> ~entllation system connected <br /> directly to the outside, cap%ble of <br /> five air changes per hour shall be <br /> provided where there are no openable <br /> windows. OUBC 1205-a <br />I ~2_.lp~ Provideall habitable rooms <br /> h outside windows with net areas <br /> <br />of not less than 1/10 of floor areas <br />not 10 sq. ft. Every sleeping room <br />shall have an exterior door or not <br />less than 5.7 sq. ft. of openable <br />window. The mzn. net clear opening <br />height shall be 24 inches. The min. <br />net clear opening width shall be 20 <br />~nches. The finished sill height <br />shall be not more then 44 inches. <br />OUBC 1204 and 1205 (a) <br /> <br />29. Provide at least one 36" <br />Swinging (exit) door OUBC 3304 (e) <br /> <br />30. Stairs: OUBC 3305 <br /> a. Hax. 8" rise. Min. 9" run. <br /> b. Headroom over stairs 6'6" <br /> <br /> c. Handrail designed for 20 <br /> lbs. lateral load. Table <br /> 23-c <br /> d. Stairways having less than <br /> 4 risers need not have <br /> handrails. 330~ (j) <br /> <br />31. Heating facilities capable of <br />~alntaln~ng a temperature of 68 <br />degrees P. at a point 3' above the <br />floor are required Ln all habitable <br />roms. OU~C 1211 <br /> <br />32. Warm air furnace shall not be <br />~nstalled in a bedroom or bathroom. <br />OU~1C 704 <br /> <br />33. Waere bottom of glass light is <br />within 18" of floor and all glass <br />doors and wall panels of bathtub and <br />shower enclosures, must be of <br />lamanated, tempered or wire glass. <br />OUBC 5406 (d) <br /> <br />~,'2 Approved numbers or addresses <br />%~nall be provided for all new <br /> <br /> buildings in such a position as to <br /> be plainly visible and legible from <br /> t~%e street or road fronting the <br /> [,;~oper ty. <br />~ Every dwelling shall be <br /> <br />provided with an approved product of <br />combustion detector other than heat <br />mounted on the ceiling or wall at a <br />po±ut centrally located in the <br />corridor or area flying access to <br />sleeping rooms. Where sleeping <br />rooms are on an upper level, the <br />detector shall be placed at the <br />center of the culling directly above <br />the stairs. Care shall be exercised <br />when locating cold air return to <br />furnace so that air flow to detector <br />from non-sleeping areas is not <br />impeded. A smoke detector shall be <br />installed in the basement of <br /> <br />sleeping area. OUBC 1210 <br /> <br />36. Loose-fill insulation. Blown, <br />poured and spray-on type may be used <br />attic spaces where roof slope is 4 ±n 12 <br />or grater and there Ls at least 44" of <br />headroom at the ridge. 5303 (a) 2.A <br /> <br />37. Thermal insulation st~a[l not bc <br />installed witllln 3" of any metal c[~imney <br />or gas vent. <br /> <br />B~? /Insulation requlrements, <br /> ~ldings with high-efficiency heating <br />equipment such as: <br /> 1. Heat pumps that shoes a <br /> coefficient of performance as <br /> required zn Table No. 53-D. <br /> 2. Gas and oll fired that shows a <br /> minimum combustion efficiency <br /> of 80 percent Annual Fuel Usc <br /> Efficiency (AFUE) rating. <br />May have building elements insulated as <br />Follows: <br /> Cei 1 lng R- 3 0 (roof/ceiling <br /> assemblies in which has a slope of 3 <br /> in 12 or greater, may be R-19). <br /> Walls R-19 <br /> Floors R-19 <br />Other Heating systems: <br /> Ceilings R-38 (roof/ceiling <br /> assemblies in which as a slope <br /> of 3 in 12 or greater may be <br /> R-19) <br /> Walls R-19 <br /> Floors R-19 <br /> OUBC 5303 (c)l <br /> <br />39. Slab min. 24" length of R-4.5 <br />insulation placed between slab and <br />foundation wall, length to include <br />horizontal and vertical distance. 5303 <br />(c) 4 <br /> <br />40. weatherstrlp doors between heated <br />and unheated areas. <br /> <br /> 41. Heat ducts installed under floor or <br /> · n attic shall be provided min. R-4.5 <br /> <br /> INSULATION. <br /> <br /> 42. R-ii perimeter insulation acceptcd <br /> when crawl space is a plenum. <br />~ Draft baffles are required at eave <br /> <br />vents to deflect ventilation air over <br />blown insulation. (OUBC Section) 5303 (al <br />2A <br /> <br />44. Fireplace and chimney construction <br />shall conform to chapter 37 OUBC <br /> <br />45. When alterations, repairs, or <br />additions having a valuation of $1,000.00 <br />occur, or sleeping rooms are added ~n <br />existing Group R, Division 3 occupancies, <br />the entire building shall be provided <br />with smoke detectors as specified in UBC <br />1210 (a) <br /> <br />46. Sky lights set at an angle less than <br />45 degree from horizontal shall be set at <br />least 4" above the plane of roof on a <br />curb contacted as required for %he frame. <br /> <br /> <br />