My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
Permit - 1269279
Images9
>
Public Works - Permits
>
Building
>
FOR PUBLIC VIEW ON INTERNET
>
COMPLETED FILES - INACTIVE
>
Old Files 5
>
Permit - 1269279
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/4/2011 9:20:06 AM
Creation date
9/2/2003 4:03:35 PM
Metadata
Fields
Template:
Permits
Permit Address
9194 SHAW SQ SE
Permit City
Aumsville
Permit Type
Permit
Permit Site Number
7653
Permit Doc Type
Permit Document
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
22
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
1.' FoDtings shall bear on firm <br /> undisturbed soil. <br /> <br /> 2. Fills to be used to support <br /> footings shall be engineered (report <br /> required) or shall be concrete. <br /> OUBC 2903-a <br /> <br /> 3. Foundation sections 12"/15"/18" <br /> wide, 6"/7"/8" thick and 12"/18"/24" <br /> depth below natural grade and finish <br /> grade are required. OUBC Table 29-a <br /> <br />/~ Provide underfloor vents of 1 <br />k-sZq, ft. per 150 sq. fto of <br />underfloor area. Openings shall be <br />as close to corners as practical and <br />provide cross ventilation. OUBC <br />2516 (c)-6 <br /> ~5~ Provide underfloor drainage if <br /> ~pace is subject to potential storm <br /> or groundwater accumulation. <br /> OUBC 2910 <br /> <br /> 6. Reinforcement required for <br /> foundation walls. <br /> <br /> Extended 1/2" sill bolts, min. <br />~7" into concrete. Space max. 6' <br />o.c. and within 12" of ends. 2907 <br /> (f) <br /> <br /> 8. Provide min. 18" x 24" access <br /> to crawl space, located not over 20' <br /> from plumbing cleanouts (OUPC 406-g) <br /> or furnace (OUMC 804-b) . Pipes, <br /> ducts and other nonstructural <br /> construction shall not interfere <br /> with accessability to or within the <br /> crawl space. OUBC 2516 (c) 2. <br /> <br />9. Vapor barriers shall be <br />installed on the ground in crawl <br />spaces and on the warm side of <br />exterior walls. 5303 (f) 5. Ground <br />cover shall turn 12" up the <br />foundation wall. <br /> <br />10. The required clearance for wood <br />members above grade is 6" for <br />mudsills, 12" for girders and 18" <br />for joists. OUBC 2516 (c) <br /> <br />11. Ail posts to be mounted on <br />approved supports. OUBC 2516 (c) 4 <br /> <br />CONSTRUCTION REQUIREMENTS <br /> <br />12. Fire block studwalls and <br />partitions (including furred spaces) <br />at floor, ceiling, soffit and at mid <br />height and along stair stringers. <br />Draft stops shall be provided in the <br />following locations. (1) in the <br />concealed space of a floor ceiling <br />assembly in a single family dwelling <br /> <br />dividing the area in to equal spaces not <br />over 1000 sq, ft. <br />(2) Draft stopS shall be installed in the <br />attics, mansards, overhangs and similar <br />concealed spaces of buildings containing <br />more than one dwelling unit. Such draft <br />stops shall be above and in line with <br />walls separating tenant spaces from each <br />other. OUBC 2516 (f) <br /> <br />13. Garage door header shall be min. <br /> D.F. #2 with double cripples. <br /> <br />14. Use header, beam or rafter sizes <br />noted on the plans. <br /> <br />15. Trusses shall be engineer approved. <br />Provide trusses details to Marion County <br />Building Department before framing <br />inspection. <br /> <br />16. A ridge board not less in depth than <br />the cut end of the rafter is required. <br />It shall be a vertical load bearing <br />member when roof slope is less than 3" in <br />12". OUBC 2517 (h) 3 <br /> <br />17. Rafter ties spaced max. 4' o.c. are <br />required immediately above ceiling joists <br />which are not parallel to the rafters. <br />OUBC 2517 (h) 4 <br /> <br />18. Roof purlins must not be smaller <br />than the rafters they support. The max. <br />span for 2 x 4 / 2 x 6 roof purlins is 4' <br />& 6' For purlin supports provide <br />struts, not smaller than 2 x 4 with an <br />unbraced length not over 8 ' and not <br />flatter than 45 degrees to the gorizontal <br />to bearing wall or partitions. OUBC 2517 <br />(h) 5 <br /> <br /> 19. Ail weather exposed plywood shall be <br /> EXTERIOR type and at least C-C grade. <br /> Attention: Roof overhangs. <br /> <br /> 20. Provide screened attic vents with a <br /> net free area of 1/150 of the attic area <br /> (or 1/300 if half is along eaves and the <br /> balance at least 3' higher). 0UBC 3205-c <br /> <br /> 21. Roof shall be sloped for drainage. <br /> valleys shall be supported (flat valleys <br /> prohibited.) Shingles (any kind) shall <br /> not be installed on a slope of less then <br /> 4" in 12". composition shingles require <br /> a 15 pound asphalt felt base sheet. <br />I ?Apte,7 <br />r~/ Provide min. one hour fire <br />/ ~paration between garage and house. <br />Separation shall extend to roof line or <br />across ceiling and remaining bearing <br />walls. Use min. 1 3/8" solid core door. <br />OUBC 503 (d) exception 3. <br /> <br />23. Elements of appliances which create <br />a glow, spark or flame shall be located a <br />min. of 18" above garage floor. OUMC 508 <br /> <br />24. Appliances subject to mechanical <br />damage shall be guarded by a protective <br />barrier. OUBC 508 <br /> <br />25. Clothes dryer located in an area <br />that is habitable or containing other <br />fuel burning appliances shall be <br />exhausted to the outside. OUMC 1903 <br /> <br /> <br />
The URL can be used to link to this page
Your browser does not support the video tag.