My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
Permit - 1270545
Images9
>
Public Works - Permits
>
Building
>
FOR PUBLIC VIEW ON INTERNET
>
COMPLETED FILES - INACTIVE
>
Old Files 5
>
Permit - 1270545
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/7/2011 9:19:17 AM
Creation date
9/2/2003 4:40:05 PM
Metadata
Fields
Template:
Permits
Permit Address
850 9TH ST
Permit City
Aumsville
Permit Type
Permit
Permit Site Number
8509
Permit Doc Type
Permit Document
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
19
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
CONS?R~ICTION <br />(Continued) <br /> <br /> Vent kitchen fan to outside via <br /> ducts. <br /> <br />27. In bathrooms, water closet <br />compartments, laundry rooms and <br />similar rooms, a mechanical <br />ventilation system connected <br />directly to the outside, capable of <br />five air changes per hour shall be <br />provided where there are no openable <br />windows. OUBC 1205-a <br /> <br />Provide all habitable rooms <br />outside windows with net areas <br />of not less than 1/10 of floor areas <br />not 10 sq. ft. Every sleeping room <br />shall have an exterior door or not <br />less than 5.7 sq. ft. of openable <br />window. The min. net clear opening <br />height shall be 24 inches. The min. <br />net clear opening width shall be 20 <br />inches. The finished sill height <br />shall be not more then 44 inches. <br />OUBC 1204 and 1205 (a) <br /> <br />29. Provide at least one 36" <br />Swinging (exit) door OUBC 3304 (e) <br /> <br />30. Stairs: OUBC 3305 <br /> a. Max. 8" rise. Min. 9" run. <br /> b. Headroom over stairs 6'6" <br /> min. <br /> c. Handrail designed for 20 <br /> lbs. lateral load. Table <br /> 23-c <br /> d. Stairways having less than <br /> 4 risers need not have <br /> handrails. 3306 (j) <br /> <br />31. Heating facilities capable of <br />maintaining a temperature of 68 <br />degrees F. at a point 3' above the <br />floor are required in all habitable <br />roms. OUBC 1211 <br /> <br />32. Warm air furnace shall not be <br />installed in a bedroom or bathroom. <br />OUMC 704 <br /> <br />33. Where bottom of glass light is <br />within 18" of floor and all glass <br />doors and wall panels of bathtub and <br />shower enclosures, must be of <br />laminated, tempered or wire glass. <br />OUBC 5406 (d) <br /> <br />Approved numbers or addresses <br />11 be provided for all new <br />buildings in such a position as to <br />be plainly visible and legible from <br />the street or road fronting the <br />property. <br /> <br />i. Every dwelling shall be <br />with an approved product of <br />combustion detector other than heat <br />mounted on the ceiling or wall at a <br />point centrally located in the <br />corridor or area giving access to <br />sleeping rooms. Where sleeping <br />rooms are on an upper level, the <br />detector shall be placed at the <br />center of the ceiling directly above <br />the stairs. Care shall be exercised <br />when locating cold air return to <br />furnace so that air flow to detector <br />from non-sleeping areas is not <br />impeded. A smoke detector shall be <br />installed in the basement of <br /> <br />d~e~ling units having a stairway which <br />opens from the basement i n~,o the <br />dwelling. Such detector sh~l:i' be <br />connected to a sounding device to provide <br />an alarm which will be audible in the <br />sleeping area. OUBC 1210 (a) <br /> <br />36. Loose-fill insulation. Blown, <br />poured and spray-on type may be used in <br />attic spaces where roof slope is 4 in 12 <br />or grater and there is at least 44" of <br />headroom at the ridge. 5303 (a) 2.A <br /> <br />37. Thermal insulation shall not b~ <br />installed within 3" of any metal chimne~ <br />or gas vent. <br /> <br />38. Insulation requirements. <br />Buildings with high-efficiency heatinc. <br />equipment such as: <br /> 1. Heat pumps that shows <br /> coefficient of performance as <br /> required in Table No. 53-D. <br /> 2. Gas and oil fired that shows a <br /> minimum combustion efficienc~ <br /> of 80 percent Annual Fuel Us{ <br /> Efficiency (AFUE) rating. <br />May have building elements insulated as <br />Follows: <br /> Ceiling R-30 (roof/ceiling <br /> assemblies in which has a slope of <br /> in 12 or greater, may be R-19). <br /> Walls R-19 <br /> Floors R-19 <br />Other Heating systems: <br /> Ceilings R-38 (roof/ceiling <br /> assemblies in which as a slope <br /> of 3 in 12 or greater may be <br /> R-19) <br /> Walls R-19 <br /> Floors R-19 <br /> OUBC 5303 (c)l <br /> <br />39. Slab min. 24" length of R-4.5 <br />insulation placed between slab and <br />foundation wall, length to include <br />horizontal and vertical distance. 5303 <br />(c) 4 <br /> <br />40. Weatherstrlp doors between heated <br />and unheated areas. <br /> <br />41. Heat ducts installed under floor or <br />in attic shall be provided min. R-4.5 <br /> <br />INSULATION. <br /> <br />42. R-ii perimeter insulation accepted <br />when crawl space is a plenum. <br /> <br />43. Draft baffles are required at eav~ <br />vents to deflect ventilation air over <br />blown insulation. (OUBC Section) 5303 (a) <br />2A <br /> <br />44. Fireplace and chimney construction <br />shall conform to chapter 37 OUBC <br /> <br />45. When alterations, repairs, or <br />additions having a valuation of $1,000.0[ <br />occur, or sleeping rooms are added in <br />existing Group R, Division 3 occupancies, <br />the entire building shall be provide6 <br />with smoke detectors as specified in UBC <br />1210 (a) <br /> <br />46. Sky lights set at an angle less than <br />45 degree from horizontal shall be set at <br />least 4" above the plane of roof on a <br />curb contacted as required for the frame. <br /> <br /> <br />
The URL can be used to link to this page
Your browser does not support the video tag.