CONSTRUCTION <br />(Continued): <br /> <br />m'~tal ducts. <br /> <br />REQUIREMENTS <br /> <br /> 27. In bathrooms, water closet <br /> compsrtments, laundry rooms and <br /> similar rooms, a mechanical <br /> ventilation system connected <br /> directly to the outside, capable of <br /> five air changes per hour shall be <br /> provided where there are no openable <br /> windows. OUBC 1205-a <br /> <br /> 28. Provide all habitable rooms <br /> with outside windows with net areas <br /> of not less than 1/10 of floor areas <br /> not 10 sq. ft. Every sleeping room <br /> shall have an exterior door or not <br /> less than 5.7 sq. ft. of openable <br /> window. The min. net clear opening <br /> height shall be 24 inches. The min. <br /> net clear opening width shall be 20 <br /> inches. The finished sill height <br /> shall be not more then 44 inches. <br /> OUBC 1204 and 1205 (a) <br /> <br /> 29. Provide at least one 36" <br /> Swinging (exit) door OUBC 3304 (e) <br /> <br /> 30. Stairs: OUBC 3305 <br /> a. Max. 8" rise. Min. 9" run. <br /> b. Headroom over stairs 6'6" <br /> min. <br /> c. Handrail designed for 20 <br /> lbs. lateral load. Table <br /> 23-c <br /> d. Stairways having less than <br /> 4 risers need not have <br /> handrails. 3306 (j) <br /> <br /> 31. Heating facilities capable of <br /> maintaining a temperature of 68 <br /> degrees F. at a point 3' above the <br /> floor are required in all habitable <br /> roms. OUBC 1211 <br /> <br /> 32. Warm air furnace shall not be <br /> installed in a bedroom or bathroom. <br /> ©UMC 704 <br /> <br /> Where bottom of glass light is <br />~lthin~ 18" of floor and all glass <br />doors and wall panels of bathtub and <br />shower enclosures, must be of <br />laminated, tempered or wire glass. <br />OUBC 5406 (d) <br />~4~/ Approved numbers or addresses <br />he,fall be provided for all new <br />buildings in such a position as to <br />be plainly visible and legible from <br />the street or road fronting the <br />property. <br /> <br /> 35 .~v e r y dwelling shall be <br /> provided with an approved product of <br /> combustion detector other than heat <br /> mounted on the ceiling or wall at a <br /> point centrally located in the <br /> corridor or area giving access to <br /> sleeping rooms. Where sleeping <br /> rooms are on an upper level, the <br /> detector shall be placed at the <br /> center of the ceiling directly above <br /> the stairs. Care shall be exercised <br /> when locating cold air return to <br /> furnace so that air flow to detector <br /> from non-sleeping areas is not <br /> impeded. A smoke detector shall be <br /> installed in the basement of <br /> <br />fan to outside via <br /> an alarm which will be audible <br /> . .tsle~ping area. OUBC 1210 (a) <br /> <br /> 36. Loose-fill insulation. <br /> poured and spray-on type may be <br /> attic spaces where roof slope is <br /> or grater and there is at least <br /> <br />dwelling units having a stairway which <br />opens from the basement into the <br />dwelling. Such detector shall be <br />connected to a sounding device to provide <br />in the <br /> <br />Blown, <br />used in <br />4 in 12 <br />44" of <br /> <br /> headroom at the ridge. 5303 (a) 2.A <br /> <br /> 37. Thermal insulation shall not be <br /> installed within 3" of any metal chimne~ <br /> or gas vent. <br /> <br /> 38. Insulation requirements. <br /> Buildings with high-efficiency heating <br /> equipment such as: <br /> 1. Heat pumps that shows <br /> coefficient of performance as <br /> required in Table No. 53-D. <br /> 2. Gas and oil fired that shows a <br /> minimum combustion efficiency <br /> of 80 percent Annual Fuel Us£ <br /> Efficiency (AFUE) rating. <br /> May have building elements insulated as <br /> Follows: <br /> Ceiling R-3 0 (roof/ceiling <br /> assemblies in which has a slope of 3 <br /> in 12 or greater, may be R-19). <br /> Walls R-19 <br /> Floors R-19 <br /> Other Heating systems: <br /> Ceilings R-38 (roof/ceiling <br /> assemblies in which as a slope <br /> of 3 in 12 or greater may be <br /> R-19) <br /> Walls R-19 <br /> Floors R-19 <br /> OUBC 5303 (c)l <br /> <br /> 39. Slab min. 24" length of R-4.5 <br /> insulation placed between slab and <br /> foundation wall, length to include <br /> horizontal and vertical distance. 5302 <br /> (c) 4 <br /> nd Weatherstrip doors between heated <br /> unheated areas. <br /> <br /> 41. Heat ducts installed under floor ox <br /> in attic shall be provided min. R-4.5 <br /> <br /> INSULATION. <br /> <br /> 42. R-ii perimeter insulation accepted <br /> when crawl space is a plenum. <br /> <br />~43~ Draft baffles are required at save <br />~nts to deflect ventilation air over <br />blown insulation. (OUBC Section) 5303 <br /> 2A <br /> <br /> 44. Fireplace and chimney construction <br /> shall conform to chapter 37 OUBC <br /> <br /> 45. When alterations, repairs, o~ <br /> 'additions having a valuation of $1,000.0£ <br /> occur, or sleeping rooms are added in <br /> existing Group R, Division 3 occupancies, <br /> the entire building shall be provided <br /> with smoke d~tectors as specified in UBC <br /> 1210 (a) <br /> <br /> 46. Sky lights set at an angle less than <br /> 45 degree from horizontal shall be set at <br /> least 4" above the plane of roof on a <br /> curb contacted as required for the frame. <br /> <br /> <br />