20. <br /> <br />Porches, Dalconies or raised <br />floor surfaces located more <br />than 3Q in. above the floor or <br />grade shall have guardrails not <br />less than 36 in. in hr. <br />Required guardrails shall have <br />intermediate rails or ornamen- <br />tal closures which will not <br />allow passage of an object 6 <br />in, or more in diameter. R- <br />214.2 <br /> <br />Smoke detectors shall be <br />installed outside of each <br />separate sleeping area in the <br />immediate vicinity of the <br />bedrooms and on each additional <br />story of the dwelling including <br />basements. In dwelling units <br />w~th split levels, a smoke <br />detector need be installed only <br />on the upper level, provided <br />the lower level is less than <br />one full story below the upper <br />level, except that if there is <br />a door between levels then a <br />detector is required on each <br />level. Ail detectors shall be <br />connected to a sounding device <br />or other detectors to provide, <br />when actuated, an alarm which <br />will be audible in all sleeping <br />areas. R-215.1 <br /> <br />22. <br /> <br />In new construction, required <br />smoke detectors shall receive <br />their primary power from the <br />building wiring. Smoke detec- <br />tors may be battery operated <br />when installed in existing <br />buildings. R-215.2 <br /> <br />' Firestopping shall be provided <br />in the following locations: in <br /> <br /> concealed spaces of stud walls <br /> at the eeillng, floors,soffits, <br /> drop ceilings, between stair <br /> stringers and at openings <br /> around vents, pipes, ducts, <br /> chlmneya and fireplaces at <br /> telling and floor spaces. R- <br /> 402.7 <br /> <br />24. Foundation cripple walls shall <br /> be framed of studs with a min. <br /> length of 14 in. or shall be <br /> framed of solid blocking. R- <br /> 402.9 <br /> <br />25. The area w~thln the foundation <br /> walls shall have all vegeta- <br /> tion, top soil and foreign <br /> material removed. R-603.2 <br /> <br />Rafters shall be nailed to <br />ceiling joists to form a con- <br />tinuous tie between exterior <br />walls where joist are parallel <br />to the rafters. Where not <br />parallel, rafters shall be tied <br />with a rafter tie, located at <br />or near the plate as practical. <br />Rafter t~es shall be spaced not <br />more than 4 feet on center. <br /> <br />28. <br /> <br />29. <br /> <br />30. <br /> <br />less in depth than the cut end <br />of the rafter. At all valley% <br />and hips there shall be a <br />valley or hip rafter not less <br />than 2 in. nominal thickness <br />and not less in depth than the <br />cut end of ~he rafter. R-702.2 <br /> <br />When the roof pitch is less <br />than 3 in 12, members support- <br />ing rafters and ceiling joist, <br />such as ridge beams, hips and <br />valleys, shall be designed as <br />beams. R-702.3 <br /> <br />wood trusses shall De deszgned <br />in accordance with approved <br />engineering practice. Tr~sses <br />shall be braced according to <br />their appropriate engineered <br />design. Truss members shall <br />not be cut or altered unless <br />so designed. R-702.9 <br /> <br />All plywood, when designed to <br />be exposed ~n outdoor applica-- <br />tions shall be of an exterior <br />type, except that plywood roof <br />sheathi~%g exposed to the <br />underside may be of interior <br />type with exterior glue. R- <br />703.] <br /> <br />Provlde screened attzc vents <br />with a net free area of 1/150 <br />of the attic area (or 1/300 if <br />half is along eaves and the <br />other half in the upper <br />portion). R-707 <br /> <br />A readily accessible attic <br />access framed opening not less <br />than 22 in. by 30 in. shall De <br />p~ovided. R-708 <br /> <br />36. <br /> <br />Fireplace and chimney con- <br />struction shall conform to <br />chapter 9. <br /> <br />INSULATION REQUIREMENTS: <br />Buildings with high-efficiency <br />heating equipment shall be <br />~nsulated as follow: ceiling <br />R-30 (roof/ceiling assemblies <br />in which has a slope of 3 in <br />12 or greater, may be R~lg), <br />walls R-il, underfloors R-19, <br />other heating systems, ceiling <br />R-35 /vaulted ceiling <br />walls R-19 and under floor <br />19. <br /> <br />Elements of appliances which <br />create a glow, spark or flame <br />shall be located a min. of 18 <br />in. above garage floor. M- <br />1114 <br /> <br />Appliances subject to mechani- <br />cal damage shall be guarded by <br />a protective barrier. <br /> <br />Ridge board shall be at least 1 <br />lnch nominal thickness and not <br /> <br /> <br />