Laserfiche WebLink
925 8TH ST., AUMSVILLE <br />April 18, 1991 <br />Page 3 <br /> <br />the job site, submit the engineer's design and construction <br />plans to the Marion County Building Department prior to <br />start of construction and have the approved drawings <br />available at the site for the framing inspection. <br /> <br />15. <br /> <br />INSULATION REQUIREMENTS: Provide insulation as follows: <br />ceiling R-38 (vaulted ceiling R-19) walls R-19 and under <br />floor R-19. <br /> <br />Buildings with high-efficiency heating equipment (Heat Pumps <br />w/ COP of 2.7 or Gas or Oil w/ 80% AFUE rating) may be <br />insulated as follows: ceiling R-30 (roof/ceiling assemblies <br />in which has a slope of 3 in 12 or greater, may be R-19), <br />walls R-ii, underfloors R-19. <br /> <br />Approval as a result of this plan review or an inspection shall <br />not be construed to be an approval of a violation of the <br />provisions of the dwelling code or of other ordinances of the <br />jurisdiction. Reviews or inspections presuming to give authority <br />to violate or cancel the provisions of the dwelling code or of <br />other ordinances of the jurisdiction shall not be valid. <br /> <br />"APPROVED" only when this sheet is attached to plans. <br /> <br /> <br />