Laserfiche WebLink
Marion,,,County <br /> OREGON <br /> COMMUNITY DEVELOPMENT <br /> DEPARTMENT <br /> <br />DIRECTOR <br /> <br />BUILDING INSPECTION <br /> <br />PLANNING & <br />ENFORCEMI~NT <br />! 5CI3~ S88,S03~ <br /> <br />BOARD OF <br />COMMISSIONERS <br />Randall Franke <br /> <br />11/18/9l <br /> <br />DONALD E. BOILNER <br />8582 HOLMQUIST ROAD SE <br />AUMSVILLE, OREGON 97325 <br /> <br />SUBJ: <br /> <br />WINTER WATER RECHECK REQUEST <br />8512/8532 HOLMQUIST ROAD SE <br />T. 8S., R. 1W., SECTION 31 <br /> <br />As I calculated the depth of the test pits from the data <br />I gathered with you 11/15/91, I found that only one of <br />the test pits is deep enough ( 72 inches deep ) to re- <br />evaluate this site for other than the approved sand <br />filter septic systems. We must be able to measure for <br />water levels at least six feet deep to ensure that there <br />will be four feet of unsaturated soil between the bottom <br />of the drainline trenches and the winter water table. <br /> <br />We cannot proceed with the review until <br />deepened and the stand-pipes installed. <br />office when you have prepared the sites. <br />complete the work as soon as possible so <br />require information. Call, if you have any <br />am usually in the office between 8 and 10 AM. <br /> <br />SOIL SCIENTIST <br /> <br />the pits are <br />Contact our <br />You should <br />collect the <br />questions. I <br /> <br />DON WOODLEY <br />BUILDING OFFICIAL <br /> <br />Senator Building 220 High Street NE Salem, Oregon 97301-3670 <br /> <br /> <br />