20. <br /> <br />Porches, balconies or raised <br />floor surfaces located more <br />than 30 in. above the floor or <br />grade shall have guardrails not <br />less than 36 in. in bt. <br />Required guardrails shall have <br />intermediate rails or ornamen- <br />tal closures which will not <br />allow passage of an object 6 <br />in. or more in diameter. R- <br />214.2 <br /> <br />21 .~---tm o k e detectors shall De <br /> installed outside of each <br /> separate sleeping area in the <br /> immediate vicinity of the <br /> bedrooms and on each additional <br /> story of the dwelling including <br /> basements. In dwelling units <br /> with split levels, a smoke <br /> detector need be installed only <br /> on the upper level, provided <br /> the lower level is less than <br /> one full story below the upper <br /> level, except that if there is <br /> a door between levels then a <br /> detector is required on each <br /> level. All detectors shall be <br /> connected to a sounding device <br /> or other detectors to provide, <br /> when actuated, an alarm which <br /> will be audible in all sleeping <br /> areas. R-215.1 <br /> <br />22. <br /> <br />In new construction, required <br />smoke detectors shall receive <br />their primary power from the <br />building wiring. Smoke detec- <br />tors may be battery operated <br />when installed in existing <br />buildings. R-215.2 <br /> <br />23. Firestopping shall be provided <br /> in the following locations: in <br /> concealed spaces of stud walls <br /> at the ceiling, floors,soffits, <br /> drop ceilings, between stair <br /> stringers and at openings <br /> around vents, pipes, ducts, <br /> chimneys and fireplaces at <br /> ceiling and floor spaces. R- <br /> 402.7 <br /> <br />24. Foundation cripple walls shall <br /> be framed of studs with a min. <br /> length of 14 in. or shall be <br /> framed of solid blocking. R- <br /> 402.9 <br /> <br />25. <br /> <br />The area within the foundation <br />walls shall have all vegeta- <br />tion, top soil and foreign <br />material removed. R~603.2 <br /> <br />26. <br /> <br />Rafters shall be nailed to <br />ceiling joists to form a con- <br />tinuous tie between exterior <br />walls where joist are parallel <br />to the rafters. Where not <br />parallel, rafters shall be tied <br />with a rafter tie, located at <br />or near the plate as practical. <br />Rafter ties shall be spaced not <br />more than 4 feet on center. <br /> <br />27. Ridge board shall be at least 1 <br /> inch nominal thickness and not <br /> <br />less in depth than the cut er',J <br />of the rafter. At all valleys <br />and hips there shall De a <br />valley or hip rafte~ not less <br />than 2 in. nominal thickness <br />and not less in depth than thc <br />cut end of the rafter. R-702.2 <br /> <br />28. <br /> <br />When the roof pitch) is <br />than 3 in 12, members suppor'.- <br />lng rafters and ceiling 3ols% <br />such as ridge beams~ hips <br />valleys, shall be desl~ne~ <br />beams. R-702.3 <br /> <br />Wood trusses shall be designed <br />in accordance with approved <br />engineering practice. <br />shall be braced according <br />their appropriate engineered <br />design. Truss members <br />not be cut or altered un!~s~ <br />so designed.R-702.9 <br /> <br />All plywood, when designed to <br />be exposed in outdoor applica- <br />tions shall be of a~ exterior <br />type, except that plywood roof <br />sheathing exposed to t~e <br />underside may be of interior <br />type with exterior glue. ~- <br />703.1 <br /> <br />Provide screened attic vcl)t~ <br />with a net free area of <br />of the attic area (or 1/300 i~ <br />half is along eaves and the <br />ut her half in the ~pper <br />portion). R-707 <br /> <br />32. A readily accessible atnlc <br /> access framed opening not less <br /> than 22 in. by 30 in. snail be <br /> provided. R-708 <br /> <br />33. Fireplace and chimney con- <br /> struction shall conform to <br /> chapter 9. <br /> <br />34. INSULATION REQUIR~MENTS~ <br /> Buildings with high-efficlency <br /> heating equipment shall be <br /> insulated as follow: ceiling <br /> R-30 (roof/ceiling assemblies <br /> in which has a slope of 3 in <br /> 12 or greater, may be <br /> walls R-Ii, underfloors R-19, <br /> other heating systems, ceiling <br /> R-38 (vaulted ceiling R-19) <br /> walls R-19 and under floor <br /> 19. <br /> <br />5. Elements of appliances which <br /> create a glow, spark or flame <br /> shall be located a min. of 18 <br /> in. above garage floor. M- <br /> 1114 <br /> <br />6. Appliances subject to mechani- <br /> cal damage shall be guarded D~ <br /> a protective barrier. M-1114 <br /> <br /> <br />