Laserfiche WebLink
710 Michael Way, Aumsville <br />September 4, 1992 <br />Page 1 <br /> <br />Ma (9,,n County <br /> OREGON <br />COMMUNITY DEVELOPMENT <br />DEPARTMENT <br /> <br />Building Inspection - Dwelling Plan Review <br /> <br />The attached plans have been reviewed for compliance with the State of Oregon <br />1990 Edition One and Two Family Dwelling Specialty Code. <br /> <br />Provide an access crawl hole to the underfloor space. The minimum size <br />opening required is 18 inches by 24 inches. (R-309.2) <br /> <br />Appliances generating a glow, spark or flame and all electrical outlets <br />installed in a garage shall be elevated 18 inches above the floor. <br />Appliances installed in a garage shall be protected against damage by <br />vehicles. (M-1114 & NEC Article 500) <br /> <br />Smoke detectors shall be installed outside of each separate sleeping <br />area in the immediate vicinity of the bedrooms and on each additional <br />story of the dwelling including basements. In dwelling units with split <br />levels, a smoke detector need be installed only on the upper level, <br />provided the lower level is less than one full story below the upper <br />level, except that if there is a door between levels then a detector is <br />required on each level. Ail detectors shall be connected to a sounding <br />device or other detectors to provide, when actuated, an alarm which will <br />be audible in all sleeping areas. (R-215.1) <br /> <br />Wood framed walls less than four feet in width at garage door openings <br />shall be provided with approved hold-down anchors. Anchors are to be <br />provided at each end of each wall segment and connect the wall studding <br />to the concrete foundation. As an alternate, a designed structural <br />system to resist the required 80 mile per hour wind load can be <br />provided. <br /> <br />A readily accessible attic access shall be provided to any attic area <br />having a clear height of over 30 inches. A framed opening not less than <br />22 in. by 30 in. is required. (R-708) <br /> <br />Roof trusses are required to be designed by an Oregon registered <br />Engineer or Architect. For trusses manufactured by an approved <br />fabrication plant, have the design and layout drawings available at the <br />construction site for the framing inspection. All job site cutting or <br />modification of the roof trusse~ shall be clearly shown in the <br />engineer's design calculations and drawings. If trusses are to be built <br />at the job site, submit the engineer's design and construction plans to <br />the Marion County Building Department prior to start of construction and <br />have the approved drawings available at the site for the framing <br />inspection. <br /> <br />Fireplace and chimney construction shall conform to chapter 9. <br /> <br />Each solid fuel burning masonry or factory built fireplace shall be <br />equipped with an outside air inlet. (R-906) <br /> <br />"APPROVED" only when this sheet is attached to plans <br /> <br /> <br />